REFERENCES<br />
4<br />
4.10 DEFAULT PARAMETERS FOR POS SYSTEMS<br />
<strong>The</strong> default values for the RS232 and Data Format parameters for POS systems are<br />
listed in the following table:<br />
NIXDORF Mode A FUJITSU ICL Mode<br />
RS232 Group<br />
Baud Rate 9600 9600 9600<br />
Parity Odd None Even<br />
Data Bits 8 8 8<br />
Stop Bits 1 1 1<br />
Handshaking Hardware (RTS/CTS) None RTS always on<br />
ACK/NACK Protocol Disabled Disabled Disabled<br />
FIFO Enabled Enabled Enabled<br />
Inter-Character Delay Disabled Disabled Disabled<br />
RX Timeout 9.9 sec 2 sec 9.9 sec<br />
Serial Trigger Lock Disabled Disabled Disabled<br />
Data Format Group<br />
Code Identifier Custom Custom Custom<br />
Header No Header No Header No Header<br />
Terminator CR CR CR<br />
Field Adjustment Disabled Disabled Disabled<br />
Code Length TX Not Transmitted Not Transmitted Not Transmitted<br />
Character Replacement Disabled Disabled Disabled<br />
<strong>The</strong> table below lists all the Code Identifiers available for POS systems:<br />
CODE NIXDORF Mode A FUJITSU ICL Mode<br />
UPC-A A0 A A<br />
UPC-E C0 E E<br />
EAN-8 B FF FF<br />
EAN-13 A F F<br />
Code 39 M None C [code length]<br />
Codabar N None N [code length]<br />
Code 128 K None L [code length]<br />
Interleaved 2 of 5 I None I [code length]<br />
Code 93 L None None<br />
Industrial 2 of 5 H None H [code length]<br />
UCC/EAN 128 P None L [code length]<br />
MSI/Plessey O None None<br />
Code 11 None None None<br />
121