REFERENCES<br />

4<br />

4.10 DEFAULT PARAMETERS FOR POS SYSTEMS<br />

<strong>The</strong> default values for the RS232 and Data Format parameters for POS systems are<br />

listed in the following table:<br />

NIXDORF Mode A FUJITSU ICL Mode<br />

RS232 Group<br />

Baud Rate 9600 9600 9600<br />

Parity Odd None Even<br />

Data Bits 8 8 8<br />

Stop Bits 1 1 1<br />

Handshaking Hardware (RTS/CTS) None RTS always on<br />

ACK/NACK Protocol Disabled Disabled Disabled<br />

FIFO Enabled Enabled Enabled<br />

Inter-Character Delay Disabled Disabled Disabled<br />

RX Timeout 9.9 sec 2 sec 9.9 sec<br />

Serial Trigger Lock Disabled Disabled Disabled<br />

Data Format Group<br />

Code Identifier Custom Custom Custom<br />

Header No Header No Header No Header<br />

Terminator CR CR CR<br />

Field Adjustment Disabled Disabled Disabled<br />

Code Length TX Not Transmitted Not Transmitted Not Transmitted<br />

Character Replacement Disabled Disabled Disabled<br />

<strong>The</strong> table below lists all the Code Identifiers available for POS systems:<br />

CODE NIXDORF Mode A FUJITSU ICL Mode<br />

UPC-A A0 A A<br />

UPC-E C0 E E<br />

EAN-8 B FF FF<br />

EAN-13 A F F<br />

Code 39 M None C [code length]<br />

Codabar N None N [code length]<br />

Code 128 K None L [code length]<br />

Interleaved 2 of 5 I None I [code length]<br />

Code 93 L None None<br />

Industrial 2 of 5 H None H [code length]<br />

UCC/EAN 128 P None L [code length]<br />

MSI/Plessey O None None<br />

Code 11 None None None<br />