Doc<br />
no.<br />
KKC-Q-KPOOl<br />
NUCLEAR POWER PLANT<br />
GOESGEN-DAENIKEN LTD Page : 3<br />
Of : 6<br />
1.<br />
1.1<br />
1.2<br />
Component data<br />
Name and address <strong>of</strong> operator :<br />
Kernkraftwerk GBsgen-Daniken AC<br />
46S8 Daniken<br />
Commission date <strong>of</strong> nuclear facility :<br />
1979<br />
1.3<br />
1.3 .1<br />
1.3 .2<br />
1.3 .3<br />
1.3 .4<br />
1.3 .5<br />
1.3 .6<br />
Components :<br />
System :<br />
Component designation<br />
Boiler number (SVDB) :<br />
Manufacturer :<br />
Serial number :<br />
Year <strong>of</strong> manufacture :<br />
PresBurizer<br />
YP<br />
YP10 B001<br />
-<br />
Oebriider Sulzer AC<br />
8401 Winterthur<br />
15'4O1<br />
1976<br />
1.3 .7. Location :<br />
A0312. A0422, AO522, A0622<br />
(Boon No.)<br />
1.3 .8<br />
Component design data :<br />
1.3.8.1 Safety catesory : 1<br />
1.3.8.2 Design temperature : 362°C<br />
1.3.8.3 Design pressure : 175 bar<br />
1.3.8.4 Capacity :<br />
Appro*. 42 m3<br />
1.3.8.S Ksdlun :<br />
Water/steam<br />
1.3.8.6 Steam/heat capacity : 15.12 kW<br />
1.3.8.7 Activity :<br />
57 (sal) Ci/m 3<br />
11 (primary coolant water) Ci/n3<br />
1.3.8.8 Materials :<br />
20 Hn Ni 55, plated with<br />
X 10 Cr Ni Tl 18 9<br />
90