Doc.-No.<br />

KKG-Q-PSOO5<br />

NUCLEAR POWER PLANT GOESGEN-DAENIKEN LTD<br />

Annex. 5<br />

Page- 2<br />

out <strong>of</strong>: 2<br />

Rev.<br />

With nozzle welds the fillet must always be included in the examination<br />

area, i.e. the yoke magnet is to be placed in the weld area as shown<br />

under 1.1 and in the fillet area as shown in 1.2.<br />

Since the contact area <strong>of</strong> the yoke magnet with the test surface is limited<br />

with nozzle welds, adequate field strength must be demonstrated in respect<br />

<strong>of</strong> each weld by means <strong>of</strong> a tangential field strength measuring instrument.<br />

Jf magnetization is insufficient, another test technique or method, e.g.<br />

circular magnetization or liquid penetration, must be applied.<br />

2. Basic material testing<br />

Large surfaces on vessels etc. are to be divided into squares <strong>of</strong> max. 100 mm<br />

side length.<br />

6<br />

c'<br />

D<br />

A<br />

D<br />

\E -Q D'<br />

B<br />

o<br />

\<br />

A'<br />

O<br />

4<br />

cm<br />

Test area<br />

\<br />

D<br />

O<br />

a<br />

D'<br />

a<br />

Sequence:<br />

AA-A'A 1<br />

BB-B'B 1<br />

CC-C'C<br />

DD-D'D'<br />

Check with the Berthold magnetic<br />

field indicator whether there<br />

is sufficient magnetization,<br />

and if not, select further<br />

intermediate positions.<br />

135