20.01.2015 Views

In-Service Inspection of Nuclear Power Plants - gnssn - International ...

In-Service Inspection of Nuclear Power Plants - gnssn - International ...

In-Service Inspection of Nuclear Power Plants - gnssn - International ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

This publication is no longer valid<br />

Please see http://www-ns.iaea.org/standards/<br />

Doc. no.<br />

KKG-Q-PSOO5<br />

NUCLEAR POWER PLANT GOESGEN-DAENIKEN LTD<br />

Page<br />

<strong>of</strong><br />

5.5. Checking, <strong>of</strong> examination equipment<br />

Tbs following instruments are checked «t least once per year.<br />

Examination equipment supplied by outside firns is checked before<br />

their use in the KKC.<br />

Examination instruments :<br />

Check on the basis <strong>of</strong><br />

Yoke magnets :<br />

KKG-Q-PSO22 and DIN 5U31/T2 for<br />

adequate magnetic induction<br />

Bloch light lamps<br />

Determination <strong>of</strong> maximum permissible<br />

distance for light <strong>In</strong>tensity<br />

i 8W/m using * Bloch light-meter.<br />

the Bloch light-meter is checked once<br />

per year by the supplier.<br />

Tangential field strength<br />

With reference to the permanent<br />

magnetic calibration Bloch (before every measurement).<br />

For the other magnetization instruments, the adequacy <strong>of</strong><br />

magnetization must be demonstrated on the examination area with the<br />

magnetic field <strong>In</strong>dicator.<br />

The results <strong>of</strong> instrument checks are entered as HT-records.<br />

121

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!