Doc. no.<br />
KKG-Q-PSOO5<br />
NUCLEAR POWER PLANT GOESGEN-DAENIKEN LTD<br />
Page<br />
<strong>of</strong><br />
5.5. Checking, <strong>of</strong> examination equipment<br />
Tbs following instruments are checked «t least once per year.<br />
Examination equipment supplied by outside firns is checked before<br />
their use in the KKC.<br />
Examination instruments :<br />
Check on the basis <strong>of</strong><br />
Yoke magnets :<br />
KKG-Q-PSO22 and DIN 5U31/T2 for<br />
adequate magnetic induction<br />
Bloch light lamps<br />
Determination <strong>of</strong> maximum permissible<br />
distance for light <strong>In</strong>tensity<br />
i 8W/m using * Bloch light-meter.<br />
the Bloch light-meter is checked once<br />
per year by the supplier.<br />
Tangential field strength<br />
With reference to the permanent<br />
magnetic calibration Bloch (before every measurement).<br />
For the other magnetization instruments, the adequacy <strong>of</strong><br />
magnetization must be demonstrated on the examination area with the<br />
magnetic field <strong>In</strong>dicator.<br />
The results <strong>of</strong> instrument checks are entered as HT-records.<br />