20.01.2015 Views

In-Service Inspection of Nuclear Power Plants - gnssn - International ...

In-Service Inspection of Nuclear Power Plants - gnssn - International ...

In-Service Inspection of Nuclear Power Plants - gnssn - International ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

This publication is no longer valid<br />

Please see http://www-ns.iaea.org/standards/<br />

Doc.-No.:<br />

KKG-Q-PS005 NUCLEAR POWER PLANT GOESGEN-DAENIKEN LTD<br />

Type <strong>of</strong> document<br />

Page:<br />

out <strong>of</strong>: 14<br />

Examination specification<br />

Title<br />

Surface crack exam, using Magnetic particle inspection<br />

Magnetization: - with yokemagnet<br />

- direct circular magnetization<br />

- indirect circular magnetization<br />

Component designation<br />

no specific designation<br />

No. <strong>of</strong> pages<br />

14<br />

Responsible <strong>of</strong>ficial<br />

I. Seidl<br />

Examiner<br />

H.O.<br />

Polte<br />

No. <strong>of</strong> Annexes<br />

6<br />

Date <strong>of</strong> preparation<br />

15.5.1987<br />

Date <strong>of</strong> test<br />

5.6.1987<br />

Distribution<br />

SVDB-N<br />

lx<br />

Revisions<br />

Date Visa Tested Extent <strong>of</strong> revisions<br />

15.5.87 Complete revision, replaces specification PSOO5,<br />

Rev. 0 and PSOO7, Rev. 0<br />

116

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!