troubleshooting<br />
BLDV7 Series <strong>Gas</strong> Fireplace<br />
SIGNATURE COMMAND SYSTEM<br />
OPERATION<br />
FAULT<br />
DIAGNOSIS<br />
ACTION<br />
Install batteries and/<strong>or</strong><br />
plug in the AC board<br />
No beep in about<br />
8 seconds<br />
A<br />
Make sure<br />
Command<br />
Center and<br />
the control<br />
board are<br />
connected by<br />
a 2 feet <strong>or</strong> 15<br />
feet cable<br />
Using<br />
battery<br />
Battery polarity wrong<br />
Battery voltage low<br />
AC plug is plugged to<br />
AC mains<br />
Re-install batteries<br />
Change batteries<br />
Plug the AC plug to<br />
AC mains<br />
Flip the master switch<br />
(rocker switch) to the<br />
ON position<br />
The 5-pin connect<strong>or</strong> on<br />
the AC board broken <strong>or</strong><br />
bent<br />
Repair <strong>or</strong> replace the<br />
AC Board<br />
After the beep<br />
LED on the Command<br />
Center does not show<br />
solid green<br />
Replace the AC Board<br />
Press the ON button on<br />
the Command Center<br />
No beep<br />
<strong>or</strong><br />
no sound from the<br />
valve indicating pilot<br />
solenoid open<br />
B<br />
Check NG/LP<br />
conversion cap<br />
and control<br />
board<br />
connections<br />
Check valve<br />
connections<br />
Check power<br />
supply (go<br />
through A )<br />
Replace the Control<br />
Board <strong>or</strong><br />
Command Center<br />
No sparking on<br />
the pilot<br />
C<br />
Check pilot<br />
connections<br />
Check<br />
grounding<br />
Go through<br />
B<br />
Sparking is happening<br />
elsewhere (under the<br />
pilot), re-install/replace<br />
the pilot<br />
Sparking doesn’t<br />
continue<br />
D<br />
The Control Board is having interference from the<br />
surrounding metal (Ground)<br />
Re-install the Control<br />
Board, move it around<br />
<strong>or</strong> change the<br />
Control Board<br />
Pilot doesn’t light<br />
E<br />
Check gas supply<br />
Go through C<br />
Sparking is not in the<br />
path of gas flow, adjust<br />
sparker position <strong>or</strong><br />
replace the pilot<br />
Main burner doesn’t<br />
light<br />
F<br />
Go through<br />
E<br />
The sens<strong>or</strong> on the pilot<br />
is not in the flame<br />
(pilot flame too small)<br />
Adjust sens<strong>or</strong> position<br />
<strong>or</strong> replace the pilot<br />
FP1911<br />
troubleshoot sc<br />
8/08<br />
48<br />
74D3000