4016<br />

Chapter 4<br />

$AA7<br />

Name Excitation Voltage Output<br />

Description Send a value to the analog output channel of the addressed<br />

strain gauge input module. Upon receipt, the analog output<br />

channel will output this value.<br />

Syntax $AA7(data)(cr)<br />

$ is a delimiter character.<br />

AA(range 00-FF) represents the 2-character hexadecimal<br />

address of the strain gauge input module.<br />

7 is the excitation voltage output command.<br />

(data) is the value that has to be output through the analog<br />

output channel. The data format is engineering unit and the<br />

range is between 0 to 10 V.<br />

(cr) is the terminating character, carriage return (0Dh)<br />

Response !AA(cr) if the command is valid.<br />

?AA(cr) if a value was sent that is out of range.<br />

There is no response if the module detects a syntax error or<br />

communication error or if the specified address does not exists.<br />

! delimiter character indicating a valid command was received.<br />

? delimiter character indicating the command was invalid.<br />

AA (range 00-FF) represents the 2-character hexadecimal<br />

address of the strain gauge input module.<br />

(cr) is the terminating character, carriage return (0Dh)<br />

Example command: $337+05.000(cr)<br />

response: !33(cr)<br />

The command sends the value +05.000V to the analog output<br />

channel of the strain gauge input module at address 33h. The<br />

module responds that the command is valid. Its output data<br />

format is in engineering unit, the value is +05.000V.<br />