Example – Multiparameter Technique<br />

Practical multi parameter frequency selection can be demonstrated by the<br />

following example:<br />

Problem: Eddy current inspection of installed thin wall nonferromagnetic heat<br />

exchanger tubing. Tubing is structurally supported by ferromagnetic tube<br />

supports at several locations. It is desired to remove the tube support<br />

response signal from tube wall data.<br />

Solution: Apply a multiparameter technique to suppress the tube support<br />

signal response.<br />