Experiments<br />

C-Scan inspections of multilayered aircraft structures can be done using the<br />

ARMANDA scanner (figure 1a), which is a portable scanner that can be fixed<br />

on the structure. A PEC inspection was performed using this scanner on a<br />

riveted eddy current standard (2 aluminum layers of 0.04” with the bottom<br />

layer containing EDM notches of lengths of 0.250”, 0.200”, 0.150” and 0.100”<br />

on the rivet holes edge and identified from {1} to {4} on figure 2a). For sample<br />

inspection, we selected a conventional reflection eddy current probe (700 Hz<br />

- 15 kHz). The PecScan driver/receiver unit (figure 1b) is used to drive the<br />

probe, generate and receive the PEC signals.<br />

Charlie Chong/ Fion Zhang<br />

http://www.pecscan.ca/PDFs/Application-note-Cracks-Revised.pdf