26.04.2015 Views

Electromagnetic Testing

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RFT- Tube Cleanliness<br />

Tube Cleanliness is as important for the process reasons (i.e. heat transfer) as it is for the<br />

Remote Field inspection. Inspections that go the smoothest are ones where the tubes are<br />

adequately cleaned prior to the inspection. Not only does this save inspection time and money,<br />

but the data acquired from clean tubes VS dirty tubes make the inspection much more accurate.<br />

Non-relevant indications can occur from Iron deposits, calcium deposits, etc. These non-relevant<br />

indications can mask real defects located underneath.<br />

So how can you tell when the tubes are cleaned enough for a Remote Field inspection? We<br />

have developed a “Dummy” probe chart that customers can use to build probe heads to check<br />

for tube cleanliness. These probes can be made to screw on to hydro-blasters lance’s and used<br />

after the cleaning process is complete to make sure there is proper clearance for the Eddy<br />

Current probe.<br />

Final Reports - After the inspections and final data analysis is completed a formal report is<br />

generated showing a tube sheet diagram with the tubes inspected color coded to a percentage<br />

wall loss. Additional tube sheet diagrams can be generated showing the worst case scenarios<br />

for tube plugging or selective re-tubing. In addition to this information our reporting format can<br />

generate corrosion rates, and a projection based on the established corrosion rates.<br />

Charlie Chong/ Fion Zhang<br />

http://www.techcorr.com/services/Inspection-and-<strong>Testing</strong>/Remote-Field-<strong>Testing</strong>.cfm