LR-24 Electrofisher - Field Environmental Instruments
LR-24 Electrofisher - Field Environmental Instruments
LR-24 Electrofisher - Field Environmental Instruments
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>LR</strong>-<strong>24</strong><br />
BACKPACK ELECTROFISHER<br />
Safety Features Descriptions (Cont.)<br />
The <strong>LR</strong>-<strong>24</strong> and Temperature<br />
Fig. 5.5<br />
If the <strong>LR</strong>-<strong>24</strong> is working hard on hot days, it<br />
may overheat and shut down.<br />
If the air temperature in the box reaches 160F<br />
or if the heat sink reaches 200F, an overtemperature<br />
error message will be displayed<br />
and the output will be disabled until the <strong>LR</strong>-<strong>24</strong><br />
cools down.<br />
When using any of the pulsed outputs, the<br />
<strong>LR</strong>-<strong>24</strong> can reduce the frequency of the output<br />
pulses automatically based on its internal<br />
temperature. This has the effect of reducing<br />
the power level of the <strong>LR</strong>-<strong>24</strong> and therefore the<br />
heat being produced inside the system.<br />
This can allow the <strong>LR</strong>-<strong>24</strong> to continue to work<br />
instead of waiting for it to cool down again.<br />
This power reduction does not begin until the<br />
<strong>LR</strong>-<strong>24</strong> is near the point of thermal overload,<br />
so under most conditions it does not affect the<br />
output at all. If unpulsed DC is being used<br />
the <strong>LR</strong>-<strong>24</strong> can reduce the output voltage if<br />
it is near thermal overload. Again ,this can<br />
allow the <strong>LR</strong>-<strong>24</strong> to continue working instead<br />
of waiting for it to cool down. In both modes<br />
of operation as the <strong>LR</strong>-<strong>24</strong> cools down, the<br />
output is increased back toward the original<br />
settings.<br />
When enabled and the temperature of the <strong>LR</strong>-<br />
<strong>24</strong> reaches the trip point, both of the audio<br />
alarms will begin to beep simultaneously and<br />
the Thermal Limit display will show the<br />
set frequency, or voltage, in the case of DC<br />
Continued on next page...<br />
Battery Compartment Interlock Switches<br />
The cover of the battery compartment contains an interlock<br />
mechanism (A) that automatically turns off power to the<br />
<strong>LR</strong>-<strong>24</strong> if the cover is opened. When replacing the battery<br />
compartment cover, adjust it so that it is on the inside of the<br />
molded guides (B) of the pack frame. The cover must be<br />
correctly placed before the <strong>LR</strong>-<strong>24</strong> will operate.<br />
RIGHT: Detail<br />
showing relative<br />
A<br />
locationsof Interlock<br />
Switch inside control<br />
box (not visible) and<br />
A<br />
magnet inside of lid.<br />
B<br />
LEFT:Detail showing<br />
molded guides on pack<br />
frame. Lid must be aligned<br />
correctly and latched for<br />
unit to operate.<br />
Fusible Links<br />
The battery pack of the <strong>LR</strong>-<strong>24</strong> incorporates a fusible link<br />
to protect the batteries from excessively high currents. In<br />
the event this fusible link blows out, it must be replaced<br />
with the same size and type as the original link in order to<br />
continue to provide protection for the battery pack and its<br />
wiring.<br />
WARNING: Replacement of this link by anyone other<br />
than Smith-Root, Inc. will void the warranty of the entire<br />
electrofishing system.<br />
Temperature Sensors<br />
There are internal temperature sensors which can shut the <strong>LR</strong>-<br />
<strong>24</strong> down if excessive temperatures are detected; If the <strong>LR</strong>-<strong>24</strong><br />
is shut down due to high temperature, an error message is<br />
displayed for as long as the temperature is above safe limits.<br />
After the <strong>LR</strong>-<strong>24</strong> has cooled, the error message is cleared and<br />
full operation is automatically restored.<br />
The Thermal Foldback Mode (System Menu 4) can<br />
help decrease the chance of shutdown due to excessive<br />
temperatures.<br />
22 www.smith-root.com