BACKPACK ELECTROFISHER<br />

Safety Features Descriptions (Cont.)<br />

The <strong>LR</strong>-<strong>24</strong> and Temperature<br />

Fig. 5.5<br />

If the <strong>LR</strong>-<strong>24</strong> is working hard on hot days, it<br />

may overheat and shut down.<br />

If the air temperature in the box reaches 160F<br />

or if the heat sink reaches 200F, an overtemperature<br />

error message will be displayed<br />

and the output will be disabled until the <strong>LR</strong>-<strong>24</strong><br />

cools down.<br />

When using any of the pulsed outputs, the<br />

<strong>LR</strong>-<strong>24</strong> can reduce the frequency of the output<br />

pulses automatically based on its internal<br />

temperature. This has the effect of reducing<br />

the power level of the <strong>LR</strong>-<strong>24</strong> and therefore the<br />

heat being produced inside the system.<br />

This can allow the <strong>LR</strong>-<strong>24</strong> to continue to work<br />

instead of waiting for it to cool down again.<br />

This power reduction does not begin until the<br />

<strong>LR</strong>-<strong>24</strong> is near the point of thermal overload,<br />

so under most conditions it does not affect the<br />

output at all. If unpulsed DC is being used<br />

the <strong>LR</strong>-<strong>24</strong> can reduce the output voltage if<br />

it is near thermal overload. Again ,this can<br />

allow the <strong>LR</strong>-<strong>24</strong> to continue working instead<br />

of waiting for it to cool down. In both modes<br />

of operation as the <strong>LR</strong>-<strong>24</strong> cools down, the<br />

output is increased back toward the original<br />

settings.<br />

When enabled and the temperature of the <strong>LR</strong>-<br />

<strong>24</strong> reaches the trip point, both of the audio<br />

alarms will begin to beep simultaneously and<br />

the Thermal Limit display will show the<br />

set frequency, or voltage, in the case of DC<br />

Continued on next page...<br />

Battery Compartment Interlock Switches<br />

The cover of the battery compartment contains an interlock<br />

mechanism (A) that automatically turns off power to the<br />

<strong>LR</strong>-<strong>24</strong> if the cover is opened. When replacing the battery<br />

compartment cover, adjust it so that it is on the inside of the<br />

molded guides (B) of the pack frame. The cover must be<br />

correctly placed before the <strong>LR</strong>-<strong>24</strong> will operate.<br />

RIGHT: Detail<br />

showing relative<br />

A<br />

locationsof Interlock<br />

Switch inside control<br />

box (not visible) and<br />

A<br />

magnet inside of lid.<br />

B<br />

LEFT:Detail showing<br />

molded guides on pack<br />

frame. Lid must be aligned<br />

correctly and latched for<br />

unit to operate.<br />

Fusible Links<br />

The battery pack of the <strong>LR</strong>-<strong>24</strong> incorporates a fusible link<br />

to protect the batteries from excessively high currents. In<br />

the event this fusible link blows out, it must be replaced<br />

with the same size and type as the original link in order to<br />

continue to provide protection for the battery pack and its<br />

wiring.<br />

WARNING: Replacement of this link by anyone other<br />

than Smith-Root, Inc. will void the warranty of the entire<br />

electrofishing system.<br />

Temperature Sensors<br />

There are internal temperature sensors which can shut the <strong>LR</strong>-<br />

<strong>24</strong> down if excessive temperatures are detected; If the <strong>LR</strong>-<strong>24</strong><br />

is shut down due to high temperature, an error message is<br />

displayed for as long as the temperature is above safe limits.<br />

After the <strong>LR</strong>-<strong>24</strong> has cooled, the error message is cleared and<br />

full operation is automatically restored.<br />

The Thermal Foldback Mode (System Menu 4) can<br />

help decrease the chance of shutdown due to excessive<br />

temperatures.<br />