APPENDIX<br />

USER'S MANUAL<br />

Appendix B: <strong>LR</strong>-<strong>24</strong> Event Codes<br />

The following are the event codes that the <strong>LR</strong>-<strong>24</strong> logs in its internal event history.<br />

Each entry contains a code followed by the hardware time when the event happened.<br />

This time represents total shocking time since the <strong>LR</strong>-<strong>24</strong> was built.<br />

Code Display Message Description Cleared By<br />

U01 <strong>LR</strong>-<strong>24</strong> Tilted Too Far <strong>LR</strong>-<strong>24</strong> has been tilted from vertical Pole Sw.<br />

beyond safe limits.<br />

U02 Immersion Detected <strong>LR</strong>-<strong>24</strong> has been immersed in water. Power<br />

U03 Low Output Current Electrodes may be out of the water. Pole Sw.<br />

U04 Pole Switch on at Power-up. Pole switch engaged when power was Pole Sw.<br />

turned on.<br />

U05 Voltage detected on output A voltage above 30V is seen on the<br />

electrodes when the output is turned<br />

off, likely due to other <strong>LR</strong>-<strong>24</strong>s.<br />

Automatic<br />

P01 Peak Amps Overload Electrodes likely have been shorted. Pole Sw.<br />

P02 Low Battery Voltage Battery Has been drained, needs Power<br />

recharging.<br />

P03 Over Temperature <strong>LR</strong>-<strong>24</strong> has gotten too hot, let cool. Pole Sw.<br />

P04 High Battery Current Too much power from battery, reduce Pole Sw.<br />

output voltage or duty cycle.<br />

P05 High Output Current Average output current above 4<br />

Amps, reduce output voltage or duty<br />

cycle.<br />

Pole Sw.<br />

P06 Inverter Overload <strong>LR</strong>-<strong>24</strong> unable to maintain requested<br />

output voltage into the current load.<br />

A lower output voltage will be suggested<br />

to help prevent failure. May<br />

require several attempts to find a<br />

voltage that will work.<br />

S01 Low Battery Current Measurement system failure, send in<br />

for repair.<br />

S02 50V Out Of Range Voltage regulator failure, send in for<br />

repair.<br />

S03 150V Out Of Range Voltage regulator failure, send in for<br />

repair.<br />

S04 300V Out Of Range Voltage regulator failure, send in for<br />

repair.<br />

S05 500V Out Of Range Voltage regulator failure, send in for<br />

repair.<br />

S06 800V Out Of Range Voltage regulator failure, send in for<br />

repair.<br />

S07 Safety Relay Failure The output safety relay is open, send<br />

in for repair.<br />

S08 No IGBT Output The output switch is open, send in<br />

for repair.<br />

S09 IGBT HV Breakdown The output switch fails at high voltage,<br />

send in for repair.<br />

S10 Output IGBT Failure The output switch has shorted, send<br />

in for repair.<br />

S11 Memory Test Failure The microprocessor has detected a<br />

failure and may not be reliable. Send<br />

in for repair.<br />

--- No Error Place holder in history, not an error. N/A<br />

Press Enter Key on Keypad.<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

Power<br />

www.smith-root.com<br />

51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!