APPENDIX<br />

USER'S MANUAL<br />

Appendix D: Factory Default Stored Waveforms<br />

0. DC, 100 volts, 400 watt power limit.<br />

1. Standard pulse 30 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />

2. Standard pulse 60 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />

3. Standard pulse 15 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />

4. Standard pulse 90 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />

5. Standard pulse 120 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />

6. Burst of three pulses, at 500Hz with 50% Duty cycle, 15Hz cycle frequency, 100 volts, 400 watt power<br />

limit.<br />

7. Burst of three pulses at 500Hz with 50% Duty cycle, 30Hz cycle frequency, 100 volts, 400 watt power<br />

limit.<br />

8. Dual output mode waveform.<br />

Primary waveform - Burst of two pulses at 4Hz with 25% duty cycle, 1Hz cycle frequency, 100 volts<br />

400 watt power limit.<br />

Secondary waveform - Standard Pulse 30 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />

9. Dual output mode waveform.<br />

Primary waveform - Burst of three pulses at 4Hz with 25% duty cycle, 1Hz cycle frequency, 100<br />

volts, 400 watt power limit.<br />

Secondary waveform - Standard Pulse 30 Hz, 25% duty cycle, 100 volts, 400 watt power limit.<br />