<strong>Estella</strong> <strong>Pulse</strong> <strong>Generators</strong> Technical Manual 9Device Packaging—Do not use the device if the packaging is wet,punctured, opened or damaged because the integrity of the sterilepackaging may be compromised. Return the device to <strong>BIOTRONIK</strong>.Storage (magnets)—Store the device in a clean area, away frommagnets, kits containing magnets, and sources of electromagneticinterference (EMI) to avoid damage to the device.Temperature Stabilization—Allow the device to reach room temperaturebefore programming or implanting the device. Temperature extremesmay affect the initial device function.Use Before Date—Do not implant the device after the USE BEFOREDATE because the device sterility and longevity may be compromised.4.3 Lead Connection and EvaluationThe pulse generator requires atrial and ventricular leads with IS-1compatible connectors. There are no requirements specific to the atriallead. It is required to use a low polarization ventricular lead for activationof Ventricular Capture Control.Lead Check—The <strong>Estella</strong> pulse generators have an automatic lead checkfeature which may switch from bipolar to unipolar pacing and sensingwithout warning. This situation may be inappropriate for patients withan Implantable Cardioverter Defibrillator (ICD).Lead/pulse Generator Compatibility—Because of the numerousavailable 3.2-mm configurations (e.g., the IS-1 and VS‐1 standards),lead/pulse generator compatibility should be confirmed with the pulsegenerator and/or lead manufacturer prior to the implantation of apacing system.IS-1, wherever stated in this manual, refers to the internationalstandard, whereby leads and generators from different manufacturersare assured a basic fit. [Reference ISO 5841-3:1992(E)].Lead Configuration—Lead configuration determines properprogramming of the pulse generator. Pacing will not occur with aunipolar lead if the lead configuration is programmed to bipolar (seeSection 11).Setscrew Adjustment—Back-off the setscrew(s) prior to insertion oflead connector(s) as failure to do so may result in damage to the lead(s),and/or difficulty connecting lead(s).Cross Threading Setscrew(s)—To prevent cross threading thesetscrew(s), do not back the setscrew(s) completely out of the threadedhole. Leave the torque wrench in the slot of the setscrew(s) while thelead is inserted.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!