10.07.2015 Views

configuration and options guide - IBM Quicklinks

configuration and options guide - IBM Quicklinks

configuration and options guide - IBM Quicklinks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Refer to the Important Notices section for important noticesFibre Device Ports ReferencePartNumberDescriptionPorts(Std/Max) 1, 2GBICs or SFPModulesIncluded 3Mini Hubs(Std/Max)00N6881 FAStT Host Adapter 1 - -03K9307 FC Long-wave GBIC 1 - -03K9308 FC Short-wave GBIC 1 - -19K1121 FAStT200 Redundant RAID Controller 2 - -2005H08TotalStorage SAN Fabric SwitchModel H084/8 4 4-2005H16TotalStorage SAN Fabric SwitchModel H168/16 8 5-2034212 McDATA Sphereon 4300 FabricSwitch Model 2124/12 64 4 -3534F08 TotalStorage SAN Switch F08, 8-port 8 4 4 -2109F16 SAN FC Switch, 16-Port 16 8 5 -35421RU FAStT200 Storage Server 2/4 7- -35422RU FAStT200 HA Storage Server 4/4 7 - -1724100 FAStT100 Storage Server 6/6 7 - -171010U FAStT EXP100 4 7 - -172260UFAStT600 Storage Server (US linecord)6/6 7 - -35601RU FAStT EXP500 Storage Expansion Unit 4 - -24P0960 FC2-133 Host Bus Adapter 1 - -17421RU FAStT700 FC Storage Server 86/12 7, 9- 4/819K1269 FAStT700 Mini Hub 3 2 - -17401RU FAStT EXP700 Storage Expansion Unit 4 - -174290UFAStT900 Storage Server (US linecord) 106/127, 9 - 4/819K1250 LC-SC FC Adapter Cable 11 1 - -19K1271 Short-wave SFP Module 1 - -19K1272 Long-wave SFP Module 1 - -48P7062BladeCenter 2-port Fibre Channel2 - -Switch Module 12Note: Refer to the Fibre Channel Solutions Quickview section for additional related <strong>options</strong>.1. St<strong>and</strong>ard GBICs, SFP Modules <strong>and</strong> integrated optical ports are short-wave.2. St<strong>and</strong>ard ports represents number of usable ports not requiring additional hardware. Maximum numberof ports may require additional GBICs, SFPs <strong>and</strong>/or mini-hubs.3. Each FAStT700 Mini Hub provides two SFP Module ports. The host-side mini hubs connect to one of twoFibre Channel controllers in the FAStT700 or FAStT900 Storage Servers. The drive side mini hubs each connectto both Fibre Channel controllers. Full redundancy requires connection to two drive-side <strong>and</strong> two hostsidemini hubs. Drive-side mini hubs support connection to one port only.4. Four short-wave SFP modules are st<strong>and</strong>ard. Either short-wave or long-wave modules can populate the otherfour ports.5. Eight short-wave SFP modules are st<strong>and</strong>ard. Either short-wave or long-wave modules can populate theother eight ports.6. Twelve ports require two optional McDATA Sphereon 4300 FlexPort 4-port Expansion kits.7. Quantity shown for storage servers includes both host-side <strong>and</strong> drive-side ports.8. FAStT700 Storage Server supports up to eight nonredundant or four redundant host connections <strong>and</strong> tworedundant storage drive loops.9. Each mini-hub has two ports. However, when installed on drive-side, only one port is used.10. FAStT900 Storage Server supports up to eight nonredundant or four redundant host connections <strong>and</strong> tworedundant storage drive loops.Chapter 40. Fibre Interconnection Guidelines 277

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!