10.07.2015 Views

configuration and options guide - IBM Quicklinks

configuration and options guide - IBM Quicklinks

configuration and options guide - IBM Quicklinks

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

xSeries 226 Hard Disk Drive (HDD) <strong>and</strong> Optical Storage OptionsSBB NumberOptionNumberDescription Height Bays Supported 1Max Qty 2Simple-swap SATA HDDs 390P1398 73P8002 80GB 7200 rpm Simple-swap SATA HDD SL 4 ... 7 490P1399 73P8003 160GB 7200 rpm Simple-swap SATA HDD SL 4 ... 7 4- 73P8006 250GB 7200 rpm Simple-swap SATA HDD SL 4 ... 7 4Hot-swap Ultra320 HDDs 332P0746 32P0726 36.4GB 10K rpm Ultra320 SCSI Hot-swap HDD SL 4 ... 9 632P0744 32P0734 36.4GB 15K rpm Ultra320 SCSI Hot-swap HDD SL 4 ... 9 632P0747 32P0727 73.4GB 10K rpm Ultra320 SCSI Hot-swap HDD SL 4 ... 9 632P0745 32P0735 73.4GB 15K rpm Ultra320 SCSI Hot-swap HDD SL 4 ... 9 632P0748 32P0728 146.8GB 10K rpm Ultra320 SCSI Hot-swapHDDSL 4 ... 9 6Associated Options24P7970 24P7973 Ultra320 External SCSI Interface Kit 4- - 1Optical Devices32P8852 10K3782 48x-20x CD-ROM Black Internal IDE Drive HH 1, 2 290P4239 22P7042 48X/32X/48X Max CD-RW Drive HH 1, 2 226K8792 73P3300 48X/32X/48X/16X Max CD-RW/DVD-ROMCombination DriveHH 1, 2 202R3278 22P6950 16X Max RAM-Read DVD-ROM Drive HH 1, 2 226K8793 73P3305 Multi-Burner Plus HH 1, 2 2External Storage Expansion Units 5Form Factor- 17331RU EXP400 Storage Expansion Unit Rack (3U)- 17401RU FAStT EXP700 Storage Expansion Unit Rack (3U)- 1724100 FAStT100 Storage Server Rack (3U)- 172260U FAStT600 Storage Server Rack (3U)- 17226LU FAStT600 Entry Storage Server Rack (3U)1. May require removing st<strong>and</strong>ard devices.2. Four SATA HDDs are supported within the installation of the optional ServeRAID-7t controller. Two HDDs are supported in the st<strong>and</strong>ard <strong>configuration</strong>.3. Mixing SATA <strong>and</strong> SCSI HDDs is not supported.4. Required to enable a 0.8mm VHDCI external SCSI connector. Connects to the second channel of the integrated SCSI controller. Installs in the rearPCI slot knockout for either slot 2 or slot 3, preventing use of that particular slot.5. FAStT <strong>options</strong> require an optional Fibre controller be installed in the system.68 Configuration <strong>and</strong> Options Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!