10.07.2015 Views

configuration and options guide - IBM Quicklinks

configuration and options guide - IBM Quicklinks

configuration and options guide - IBM Quicklinks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TowerRack MountedINT’LP/NSU-700iNET94G4073SU-1000iNET94G4074SU-1400iNET94G4075SU-2200iNET94G40762USU-1400RMiB32P1022 1SU-3000RMiB94G6677SU-5000RMiB37L6862USP/NSU-700NET94G3134SU-1000NET94G3135SU-1400NET94G3136NotAvailable2U SU-1400RMB32P1020SU-3000RMB94G6676SU-5000RMB37L6861UPS AttributesCommunicationsLinks to Servers1 1 1 1 1 3 3Color black black black white black black blackEIA Height - - - - 2U 3U 5UInt’l Models50 or 60Hz, singlephase, VAC: 2, 310-Amp, IEC 320-C13 (Device)receptacles16-Amp, IEC 320-C19 (PDU)receptaclesLine CordReceptacle (IEC320-)220-240(xxx) 220-240(xxx) 220-240(xxx) 220-240(xxx) 220-240(xxx) 220-240(xxx) 220-240(xxx)4 4 4 8 4 8 8- - - 1 - 1 2C14 C14 C20 C20 C14 C20 TB 4US Models50 or 60Hz, single120 (120) 120 (120) 120 (120) - 120 (120) 120 (120) 200-220 (208)phase, VAC: 2Receptacles(NEMA 5-15R)10-Amp, IEC 320-C13 (Device)receptacles16-Amp, IEC 320-C19 (PDU)receptaclesLine Cord Length,NEMA Plug4 6 6 - 6 8 -- - - - - - 8- - - - - - 2 56ft, 5-15P 6ft, 5-15P 6ft, 5-15P - 6ft, L5-15P 6ft, L5-30P 8ft, L6-30P1. Two IEC power cables are provided to attach devices to the UPS outlets, which are 1.8m long with IEC 320-C13 / C14 connectors.2. How-to-Read example for 200-240(208): Input VAC is 200-240 as is the UPS output when electric service is active. When electric service is interrupted <strong>and</strong>the UPS is on battery, the UPS output is 208 VAC.3. Battery output may be set to 220, 225, 230, or 240 VAC.4. SU-5000RMiB (P/N 37L6862) contains a Terminal Block (TB) for direct attachment to an electrical source by qualified personnel.5. Two PDU jumper cables ship with the UPS for attachment from the IEC 320-C19 receptacles to Power Distribution Units (PDUs) with C20 inlets.Total Configuration Runtime EstimatorSteps:1. Identify the devices contained in the <strong>configuration</strong>.2. Sum the load (watts) of all devices in the <strong>configuration</strong>. Use either Maximum Load for minimumruntime or Typical Load for typical runtime.3. Find the Total Configuration Load in the table.4. Select the most appropriate UPS model to achieve the desired runtime.314 Configuration <strong>and</strong> Options Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!