<strong>SIMOVERT</strong> <strong>MV</strong>Engineering informationDimensioning the power section and driveOverload capability of the drive converterWhen powering-up the drive,the drive converter can beloaded with a higher currentthan the rated current , N for up<strong>to</strong> 60 s. This maximum overloadcurrent for 60 s is:¦ 1.13 , N for drive convertersfor 2.3 kV 1 )¦ 1.20 , N for drive convertersfor 3.3 kV 1 )¦ 1.13 , N for drive convertersfor 4.16 kV 1 )Rated mo<strong>to</strong>r voltage 2.3 kVThis is permissible since it maybe assumed that the drive converterhas still not reached themaximum temperature specified.In operation, overload is onlypermissible if before overloadthe load current was less thanthe rated current , N . For driveswith overload duty, it is thereforenecessary <strong>to</strong> use the followingbase load current for therequired load:¦ 0.75 , N for drive convertersfor 2.3 kV¦ 0.80 , N for drive convertersfor 3.3 kV¦ 0.75 , N for drive convertersfor 4.16 kVThus, for a 560 s cycle time, thedrives can be overloaded for60 s with the following currents(refer <strong>to</strong> Fig. 6/2a):¦ 1.13 , N for drive convertersfor 2.3 kV 1 )¦ 1.20 , N for drive convertersfor 3.3 kV 1 )¦ 1.13 , N for drive convertersfor 4.16 kV 1 )Rated mo<strong>to</strong>r voltage 2.3 kVThe load duty cycles, shown inFig. 6/2, show examples, whichcan be roughly estimated due <strong>to</strong>the similar overload situation.For other overload requirementsand in borderline cases, we recommendthat an inquiry is sent<strong>to</strong> the plant.Drive converters for 6 kV and6.6 kV as well as drive converterswith sine-wave EMCoutput filter (option Y15) are notspecified for overload. Thesedrive converters are designedfor drives with square-law load<strong>to</strong>rque (pump and fan drives)and reach the maximum permissibleutilization with ratedcurrent , N .Short time current , kRated output current , NBase load current , 0Short time current , kRated output current , NBase load current , 0Rated mo<strong>to</strong>r voltage 3.3 kVRated mo<strong>to</strong>r voltage 3.3 kV6Rated mo<strong>to</strong>r voltage 4.16 kVRated mo<strong>to</strong>r voltage 4.16 kVa)b)Fig. 6/2Definition of the nominal as well as the overload and base load currents of the <strong>SIMOVERT</strong> <strong>MV</strong> drive converter fora) a 60 s overload conditionb) a 30 s overload condition1) 700 A at maximum6/4 Siemens DA 63 · 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!