11.07.2015 Views

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SIMOVERT</strong> <strong>MV</strong>6SE80 Drive ConvertersOptionsOrderCodeDescription of the option Comment Use with <strong>SIMOVERT</strong> <strong>MV</strong> in version2.3 kV3.3 kV4.16 kVair-cooled2 x 4.16 kVair-cooled6.0 kV6.6 kVair-cooled2 x 4.16 kV2.3 kV3.3 kV4.16 kVwatercooledwatercooledMechanical versionsM11M23Dust protectionDoors with filter elements. Front-mounted so that thefilter element can be replaced with the doors closedand the drive converter operational.Caution: When filter elements are used, the outputmust be limited <strong>to</strong> 98% of the rated output.Degree of protection IP23With fan cover, corresponding <strong>to</strong> IP23.Caution: Cubicle depth increases by 50 mm.¦ ¦ ¦ – –¦ ¦ ¦ Standard Standard3M41M43Degree of protection IP41Wire-mesh doors (1 mm) and fan coverDegree of protection IP43With coverFan coveronly IP21With L08 orY15:Fan coversonly IP23¦ ¦ ¦ – –– – – ¦ ¦To achieve with M23 and M41M57Degree of protection IP54Cabinet with internal air-<strong>to</strong>-water cooler.Not available<strong>to</strong>gether withoption L17– – – ■ ■M59M60Cabinet doors without air intake openingsAir intake from below through floor panelswith cut-outs.LocksDoors can be locked using integrated safety locks.Caution:please notethe informationon page 6/6¦ ¦ – – –¦ ¦ ¦ ¦ ¦M65M66Emergency operation in the event of fan failureOperation can be continued at a lower output(emergency operation) when a fan fails.Refer <strong>to</strong> Page 6/6 for specifications.Suitable for marine applicationsAccording <strong>to</strong> the requirements of themarine classification societies:Lloyds Register of Shipping, American Bureau ofShipping, Germanischer Lloyd, Bureau Veritas,Det Norske VeritasChinese Classification SocietyY09 Special paint finish according <strong>to</strong> RAL ...Deviating from the standard RAL 7032RAL No. must be specified in plain text.Only appliesfor the maindrive converterfansIncludes theoptions Y09,L33, and L55.Not withoption L17Fans alwaysRAL 7032¦ – – – –– – – ¦ ¦¦ ¦ ¦ ¦ ¦Marine version with individual certificateV10 Individual certificate fromGermanische Lloyd (GL)for non-essential servicesV20V30V50V60V70Individual certificate fromLloyds Register of Shipping (LRS)for non-essential servicesIndividual certificate fromBureau Veritas (BV)for non-essential servicesIndividual certificate fromDet Norske Veritas (DNV)for non-essential servicesIndividual certificate fromAmerican Bureau of Shipping (ABS)for non-essential servicesIndividual certificate fromChinese Classification Society (CCS)for non-essential servicesIncludes M66 – – – ¦ ¦Includes M66and L86Includes M66and Y75– – – ¦ ¦– – – ¦ ¦Includes M66 – – – ¦ ¦Includes M66 – – – ¦ ¦Includes M66and coremarkings– – – ¦ ¦½ Option possible ■ On request – Not availableSiemens DA 63 · 2004 3/19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!