<strong>SIMOVERT</strong> <strong>MV</strong>Engineering informationSystem componentsOutput reac<strong>to</strong>rsOutput reac<strong>to</strong>rs limit capacitivepre-charging currents for longcables.The maximum cable lengthswhich can be connected asstandard without having <strong>to</strong> usereac<strong>to</strong>rs, are specified in thefirst table on this page. Longercable lengths should be dimensionedaccording <strong>to</strong> the secondtable.The reac<strong>to</strong>rs have an iron coreand are suitable for drives withstandard induction mo<strong>to</strong>rs anda rated mo<strong>to</strong>r frequency (frequencyat the start of fieldweakening) of up <strong>to</strong> 150 Hz.The output reac<strong>to</strong>rs limit therates-of-rise of the voltages atthe mo<strong>to</strong>r winding due <strong>to</strong> cablecapacitances.Maximum cable length 1 ) without output reac<strong>to</strong>rDrive converter rated output Rated voltage Maximum cable length0.8 <strong>MV</strong>A <strong>to</strong> 9.1 <strong>MV</strong>A 2.3 kV <strong>to</strong> 4.16 kV 1 <strong>to</strong> 2 parallel cables3 parallel cablesmore than 3 parallel cablesScreened cables100 m80 m–0.66 <strong>MV</strong>A <strong>to</strong> 2.0 <strong>MV</strong>A 6.0 kV <strong>to</strong> 6.6 kV 1000 m 1000 mUnscreened cables–Maximum cable length 1 ) with output reac<strong>to</strong>rNo. of reac<strong>to</strong>rs in series1 reac<strong>to</strong>rDrive converter rated output Rated voltage Maximum cable lengthScreened cables0.8 <strong>MV</strong>A <strong>to</strong> 9.1 <strong>MV</strong>A 2.3 kV <strong>to</strong> 4.16 kV 1000 mSine-wave EMC filter for third-party or old mo<strong>to</strong>rsIf fixed-speed mo<strong>to</strong>rs or non-Siemens mo<strong>to</strong>rs are <strong>to</strong> be usedfor variable-speed drives<strong>to</strong>gether with <strong>SIMOVERT</strong> <strong>MV</strong>,then a sine-wave EMC filtermust be connected betweenthe drive converter and mo<strong>to</strong>r.It should be observed that onlyloads with a square-law <strong>to</strong>rquecharacteristic (fans and pumps)can be driven; field weakeningis not permissible.Constant-load <strong>to</strong>rque drives onrequest.When using sine-wave EMC filters,the drive converter outputquantities are almost sinewave.The voltage dis<strong>to</strong>rtion fora 50 Hz output frequency isless than 5% when a sine-waveEMC filter is used. The stressingon mo<strong>to</strong>rs, which are suppliedvia sine-wave EMC filters, liesunder the values according <strong>to</strong>DIN VDE 0530.When using a sine-wave EMCfilter, the drive converter outputmust be reduced (see technicaldata part 3).When ordering the sine-waveEMC output filter the mo<strong>to</strong>r ratedcurrent, the mo<strong>to</strong>r current inthe operating point and the mo<strong>to</strong>rno-load current should bestated in plain text.The possible rated outputfrequencies are restricted <strong>to</strong> therange between 30 Hz and66 Hz. The frequency controlrange is 1:10.Sine-wave EMC filters are suitablefor supplying Ex(pe) mo<strong>to</strong>rsin EEx pe type of protection(see Note on Page 6/13).Note:<strong>SIMOVERT</strong> <strong>MV</strong> drive convertersfor output voltages of 6.0 kVand 6.6 kV have an IHV outputfilter (Integrated High <strong>Voltage</strong>)as standard. For this filter, thesame engineering informationapplies as for the sine-waveEMC filter.Maximum cable lengths using sine-wave EMC filtersOutput Rated voltage Maximum cable lengthScreened cablesUnscreened cables0.66 <strong>MV</strong>A <strong>to</strong> 3.64 <strong>MV</strong>A 2 ) 2.3 kV <strong>to</strong> 4.16 kV 1000 m 1000 m6Note:All of the cable lengths, specified onthis page, apply when using the recommendedoutput cables as listedon Pages 6/20 - 6/23.The capacitances per unit lengthmust be appropriately convertedwhen using other cables than thoserecommended.1) Distance between the drive converter and mo<strong>to</strong>r,depending on the current,for max. 3 parallel 3-conduc<strong>to</strong>r EMC cables.2) Higher outputs on request.Siemens DA 63 · 2004 6/19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!