11.07.2015 Views

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SIMOVERT</strong> <strong>MV</strong>6SE80 Drive ConvertersSelection and ordering dataWater-cooled <strong>SIMOVERT</strong> <strong>MV</strong> drive converters with 12-pulse diode input circuit (DFE)for constant and square-law load <strong>to</strong>rqueRated drive Rated output Order No. Rated Base load Short- Input current Input Power loss 1 ) Efficiency 1 )converter at the mo<strong>to</strong>r output current 5 ) time at rated operatingvoltage at 50/60 Hz at 50/60 Hzoutput drive shaft current current 5 ) point3P N P , N , 0 , K , e V e P V h<strong>kVA</strong> kW A A A A kV kW %Rated mo<strong>to</strong>r voltage 2.3 kV1000 810 6SE8010-2AA01 250 188 283 256 2 x 1.2 15 98.51200 980 6SE8012-2AA01 300 225 339 306 2 x 1.2 18 98.51400 1160 6SE8014-2AA01 350 263 396 360 2 x 1.2 20 98.61600 1320 6SE8016-2AA01 400 300 452 410 2 x 1.2 22 98.61800 1490 6SE8018-2AA01 450 338 509 460 2 x 1.2 25 98.72000 1<strong>660</strong> 6SE8020-2AA01 500 375 565 510 2 x 1.2 27 98.72200 1870 6SE8022-2AA01 550 413 622 560 2 x 1.2 29 98.72400 2040 6SE8024-2AA01 600 450 678 610 2 x 1.2 31 98.72600 2200 6SE8026-2AA01 650 467 700 662 2 x 1.2 34 98.7Rated mo<strong>to</strong>r voltage 3.3 kV1300 1060 6SE8013-2BA01 230 184 276 235 2 x 1.7 20 98.51500 1240 6SE8015-2BA01 260 208 312 266 2 x 1.7 23 98.51800 1490 6SE8018-2BA01 315 252 378 320 2 x 1.7 27 98.62100 1730 6SE8021-2BA01 370 296 444 375 2 x 1.7 30 98.62300 1890 6SE8023-2BA01 400 320 480 408 2 x 1.7 33 98.62600 2150 6SE8026-2BA01 460 368 552 465 2 x 1.7 37 98.62900 2310 6SE8028-2BA01 510 408 612 515 2 x 1.7 41 98.63100 2560 6SE8031-2BA01 550 440 <strong>660</strong> 560 2 x 1.7 42 98.73600 2950 6SE8036-2BA01 630 467 700 640 2 x 1.7 48 98.74000 3320 6SE8040-2BA01 700 467 700 710 2 x 1.7 54 98.7Rated mo<strong>to</strong>r voltage 4.16 kV1700 1410 6SE8017-2CA01 240 180 270 243 2 x 2.2 26 98.52000 1640 6SE8020-2CA01 280 210 316 284 2 x 2.2 30 98.52300 1890 6SE8023-2CA01 320 240 362 325 2 x 2.2 34 98.62600 2150 6SE8026-2CA01 360 270 407 370 2 x 2.2 37 98.62900 2400 6SE8028-2CA01 400 300 452 410 2 x 2.2 40 98.63300 2730 6SE8033-2CA01 460 345 520 470 2 x 2.2 46 98.63700 3060 6SE8037-2CA01 510 383 576 520 2 x 2.2 49 98.74000 3320 6SE8040-2CA01 550 413 622 562 2 x 2.2 51 98.74500 3700 6SE8045-2CA01 625 467 700 635 2 x 2.2 58 98.75000 4100 6SE8050-2CA01 700 467 700 710 2 x 2.2 65 98.7Rated mo<strong>to</strong>r voltage 2 x 4.16 kV 3 )5900 4900 6SE8058-2CA01 2 x 415 2 x 310 2 x 470 2 x 425 2 x 2 x 2.2 2 x 46 98.56700 5500 6SE8067-2CA01 2 x 460 2 x 345 2 x 520 2 x 470 2 x 2 x 2.2 2 x 49 98.67200 6000 6SE8072-2CA01 2 x 495 2 x 370 2 x 560 2 x 505 2 x 2 x 2.2 2 x 51 98.68000 6500 6SE8080-2CA01 2 x 555 2 x 420 2 x 630 2 x 565 2 x 2 x 2.2 2 x 58 98.6<strong>9100</strong> 7500 6SE8091-2CA01 2 x 630 2 x 420 2 x 630 2 x 640 2 x 2 x 2.2 2 x 65 98.71) Without cooling system.2) Plus 18 A pre-charging current for 20 s.3) Drive converter with power section in parallel connection.4) Raw water.5) Data valid for a load cycle with short time current 60 s, base load current500 s, with short time current/base load current = 150% / 100%.3/14 Siemens DA 63 · 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!