11.07.2015 Views

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SIMOVERT</strong> <strong>MV</strong>System descriptionOpera<strong>to</strong>r control and diagnostics<strong>SIMOVERT</strong> <strong>MV</strong> drives can becontrolled and visualized at thedrive converter itself, or alsoexternally.OP7 opera<strong>to</strong>r panelThe <strong>SIMOVERT</strong> <strong>MV</strong> drive canbe locally controlled and moni<strong>to</strong>redusing the opera<strong>to</strong>r panelin the cabinet door.The assignment of the keys isdefined by the drive converter’ssoftware for open-loop andclosed-loop control. The followingfunctions can be selected:¦ Display drive actual values¦ Enter speed setpoints usingthe numerical keys¦ Read and delete messages¦ Preset two mo<strong>to</strong>r and setpointdata records¦ Preset jog setpoints¦ Menue-assisted functions forservice and commissioning.At the unit via¦ the standard OP7 opera<strong>to</strong>rpanel¦ a PC with the Drive ES engineeringsystemBy entering the necessaryparameters, the control modecan be set from remote <strong>to</strong>direct.The following actual values canbe displayed:¦ Speed¦ Mo<strong>to</strong>r voltage¦ Mo<strong>to</strong>r current¦ Mo<strong>to</strong>r output¦ cos j of the mo<strong>to</strong>r¦ DC link voltage¦ Operating timeThe messages and actual valuesare displayed on a liquidcrystaldisplay with 4 x 20digits. The plain-text display isin one of the following languages(as standard):¦ German¦ EnglishRemote control via¦ the control terminal strip¦ PROFIBUS DPFig. 2/8OP7 Opera<strong>to</strong>r panel2Control terminal stripThe drive converter includes acontrol terminal strip <strong>to</strong> controland moni<strong>to</strong>r the<strong>SIMOVERT</strong> <strong>MV</strong> drive from acontrol room. Both analog aswell as digital inputs andoutputs are available at thiscontrol terminal strip (refer <strong>to</strong>Page 6/10).PROFIBUS DP<strong>SIMOVERT</strong> <strong>MV</strong> is equipped asstandard with a PROFIBUS DPinterface <strong>to</strong> establish the couplingbetween the drive and thehigher-level au<strong>to</strong>mation system.Today, PROFIBUS DP isthe standard bus system forSiemens drive technology for allapplications at the field level.PROFIBUS DP is specified inthe European StandardEN 50170, Volume 2, andpermits cyclic data transferbetween the <strong>SIMOVERT</strong> <strong>MV</strong>units and the higher-levelsystem.In order that the drive can fulfillthe specific process task, itsparameters must be individuallyadapted during the commissioningphase. The Drive ESBasic engineering <strong>to</strong>ol is usedfor this purpose. The programallows the drive parameters<strong>to</strong> be handled in a structuredfashion when commissioningthe drive and when service isrequired. Drive ES communicatesdirectly with the<strong>SIMOVERT</strong> <strong>MV</strong> via theconnected PROFIBUS DP.Fig. 2/9Mounting rack with vec<strong>to</strong>r controlSiemens DA 63 · 2004 2/7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!