11.07.2015 Views

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Mo<strong>to</strong>rs<strong>SIMOVERT</strong> <strong>MV</strong>Rib-cooled H-compacthigh-voltage mo<strong>to</strong>rsTechnical data (continued)For operation with the<strong>SIMOVERT</strong> <strong>MV</strong> drive converter,noise will increase byc. +5 dB(A) at the quoted operatingpoints.Following measures can betaken <strong>to</strong> reduce noiseemissions:Noise reduction elementsNoisereductionapprox.dB(A)Air intake damper + sound protection sheath (LED + SDM) 6Sound-absorbing cover (SSH) 84Self- and force-ventilated mo<strong>to</strong>rs 1LA4/1PQ4The technical data of the (The data are valid for sinusoidalself- and force-ventilated supply)H-compact mo<strong>to</strong>rs (1LA4/1PQ4 series) for operation with<strong>SIMOVERT</strong> <strong>MV</strong> are listed on thefollowing pages:¦ For fan and pump drives(M ~ n 2 )¦ For constant-<strong>to</strong>rque drives(M =const)Installation altitude, cooling air temperaturePermissible output P relative <strong>to</strong> the rated output P N as a function ofthe cooling air temperature and installation altitude.Cooling airtemperatureInstallation altitude above sea level1000 m 1500 m 2000 m 2500 m 3000 m30 °C 100% 100% 100% 98% 95%35 °C 100% 100% 97% 94% 91%40 °C 100% 97% 93% 90% 87%45 °C 95% 92% 88% 85% 83%50 °C 90% 87% 84% 81%55 °C 85% 82%60 °C 80%Explanations and secondary conditionsInsulation systemUtilizationOutput and <strong>to</strong>rqueCoolant temperatureInstallation altitude<strong>Voltage</strong> rangeOverload capabilityMICALASTIC VPI, temperature rise class FAccording <strong>to</strong> temperature rise class F: refer <strong>to</strong> the technical dataAccording <strong>to</strong> temperature rise class B: the specified outputs and <strong>to</strong>rques are reduced <strong>to</strong> 88%For continuous duty S140 °C De-rating for different cooling-medium temperatures and/or installation altitudes,0 – 1000 m refer <strong>to</strong> “Installation altitude, cooling air temperature”Rated (thermal) for ± 5% voltage fluctuationFor continuous operation with voltage fluctuations in the range of ± 10%, it is necessary <strong>to</strong> de-rate the outpu<strong>to</strong>r reduce the <strong>to</strong>rque by 5%The mo<strong>to</strong>rs can withstand 150% rated current at rated voltage and rated frequency for 2 min.Tolerances According <strong>to</strong> DIN EN 60 034Efficiency – 0.1 (1 – h) Starting <strong>to</strong>rque – 15% <strong>to</strong> + 25%Power fac<strong>to</strong>r – (1 – cos j) / 6 Stall <strong>to</strong>rque – 10%Slip ± 20% Moment of inertia ± 10%Starting current + 20%Directions of rotation,fan versions1LA4 shaft height 500 mm:For clockwise and counter-clockwise rotation (fan operation is independent of the direction of rotation)1LA4 shaft height 560 and 630 mm:Either for clockwise or counter-clockwise rotation, it is not possible <strong>to</strong> provide external fans which are independen<strong>to</strong>f rotating direction.Separately-driven fans are required for mo<strong>to</strong>r design independent of rotating direction (1PQ4 series)4/4 Siemens DA 63 · 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!