11.07.2015 Views

ISU AT Command Reference

ISU AT Command Reference

ISU AT Command Reference

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ISU</strong> <strong>AT</strong> <strong>Command</strong> <strong>Reference</strong>Phase VI <strong>AT</strong> <strong>Command</strong>s1 Enable “service availability” indicator reporting using result code+CIEV:1,where is:0 Network service currently unavailable.1 Network service is available.Network service availability is equivalent to a signal strength greater than 0. The service availabilityindicator provides a way for the FA to wait until the <strong>ISU</strong> can start an SBD session without receivingcontinual notifications of changes in signal strength.Read <strong>Command</strong>: +CIER?Query the current indicator event reporting settings. The response is of the form:+CIER:,,Test <strong>Command</strong>: +CIER=?List the supported settings. The response is of the form:+CIER: (supported s),(supported s),(supported s)Note: In 1, the DTE may miss some indicator state changes if they occur while the data port isreserved (not in command mode). However, the buffering mechanism ensures that the most recent changefor each indicator during reservation will be flushed to the DTE on return to command mode; thus the DTEis always made aware of the latest state of each indicator.10.3 +CRIS – Ring Indication StatusExec <strong>Command</strong>: +CRISQuery the ring indication status, returning the reason for the most recent assertion of the Ring Indicatesignal. The response contains separate indications for telephony and SBD ring indications.The response is in the form:+CRIS:,where indicates the telephony ring indication status:0 No telephony ring alert received.1 Incoming voice call.2 Incoming data call.3 Incoming fax call.and indicates the SBD ring indication status:0 No SBD ring alert received.1 SBD ring alert received.Note: It is valid for the <strong>ISU</strong> to receive a telephony ring alert and an SBD ring alert at the same time.Assertion of the RI signal indicates only the presence of an alert; this command may be used to determinethe type(s) of ring alert.10.4 +CSQ[F] – Signal Quality (Revised)Exec <strong>Command</strong>: +CSQ[F]Execution command returns the received signal strength indication from the <strong>ISU</strong>. Response is in theform:+CSQ: Version 2.6March 30, 2006 70

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!