11.07.2015 Views

Sun Hydraulics Catalog - BIBUS SK, sro

Sun Hydraulics Catalog - BIBUS SK, sro

Sun Hydraulics Catalog - BIBUS SK, sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Logic ElementsBALANCED POPPET, NORMALLY CLOSED, VENT-TO-OPERATE2b4 cDrain3Pilot2PortPortaPerformance Curves1LocatingShoulder41NominalCapacity3TypicalCartridgeModel CodeCartridge DimensionsCavity a b cInstallationTorque(Nm)60 L/min. DKDR – XHN T-21A 35,0 22,2 45,2 45 - 50120 L/min. DKFR – XHN T - 22A 35,0 28,6 50,8 60 - 70240 L/min. DKHR – XHN T-23A 46,2 31,8 62,7 200 - 215480 L/min. DKJR – XHN T - 24A 63,5 41,3 80,3 465 - 500DKDR DKFR DKHR DKJRP = bar252015105P = bar252015105Piloted Open Pressure Differential vs. FlowP = bar252015105P = bar252015105010 20 30 40 50 60Flow = L/min.020 40 60 80 100 120Flow = L/min.Pilot Pressure vs. Pilot Flow040 80 120 160 200 240Flow = L/min.080 160 240 320 400 480Flow = L/min.Flow = L/min.1.41.21.8.6.4.2Flow = L/min.1.41.21.8.6.4.2Flow = L/min.1.41.21.8.6.4.2Flow = L/min.1.41.21.8.6.4.20 50 100 150 200 250 300 350 400P = bar0 50 100 150 200 250 300 350 400P = bar0 50 100 150 200 250 300 350 400P = bar■ Maximum operating pressure = 350 bar.■ Maximum valve leakage at 24 cSt = 0,3 cc/min.■ Minimum pilot pressure required to shift valve = DKDR, DKFR: 28 bar; DKHR, DKJR: 20 bar.■ Pilot passage into valve = DKDR, DKFR: 0,8 mm; DKHR, DKJR: 1,19 mm.■ Pilot volume displacement = DKDR: 0,16 cc; DKFR: 0,33 cc; DKHR: 0,82 cc; DKJR: 2,8 cc.■ Unique balanced construction provides predictable switching with 350 bar at both ports 1 and 2, with the vent(port 4) open and minimum pilot pressure at port 3.■ These valves are hydraulically balanced between port 1 and port 2.■ Valve will reseat when the pilot pressure falls below 10 bar.■ Port 1 and Port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.■ Port 4 may be externally connected to a pilot switching valve. The pilot valve should have a leakage rate of lessthan 10 drops/min. and be able to satisfy the pilot flow requirements. <strong>Sun</strong> model DA*-*** solenoid pilot valve isideal for this application.■ Leakage rate between port 1 and port 2 is less than 0,3 cc/min. at 350 bar.OPTION ORDERING INFORMATIONDK ✱ R – X ✱✱0 50 100 150 200 250 300 350 400P = barNominalCapacityControl Minimum Pilot Pressure Seal MaterialD 60 L/min. X Vent-to-operate DKDR, DKFR only: N Buna-NH 28 barF 120 L/min. V VitonDKHR, DKJR:H 240 L/min. 20 barJ480 L/min.Visit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.Int’l Shortcut <strong>Catalog</strong>ue #999-901-312 101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!