Flow Control ValvesFULLY ADJUSTABLE NEEDLE WITH REVERSE FLOW CHECK, HIGH CAPACITYFull Adjustment 5 Turns- +2bc1Q = L/min.2FreeFlowInletPerformance CurvesNCBB2015105a1Controlled Flow InletLocatingShoulderNCC*Q = L/min.2015105MaximumNominalOrificeTypicalCartridgeModel CodeCartridge DimensionscCavity a bL H KAdjustment Sensitivity at 7 bar DifferentialInstallationTorque(Nm)4,0 mm dia. NCBB – LCN T - 162A 31,0 19,1 40,4 - 43,9 35 - 401,5 mm dia. NCCD – LCN T - 13A 35,0 22,2 57,7 63,2 63,5 45 - 504,8 mm dia. NCCB – LCN T-13A 35,0 22,2 57,7 63,2 63,5 45 - 506,3 mm dia. NCEB – LCN T - 5A 41,4 28,6 59,7 71,6 69,3 60 - 709,7 mm dia. NCFB – LCN T-16A 62,0 31,8 67,6 77,7 74,7 200 - 21514,2 mm dia. NCGB – LCN T - 18A 79,5 41,3 84,1 88,9 88,1 465 - 500Q = L/min.NCE* NCF* NCG*5040302010Q = L/min.120906030Q = L/min.2401801206001 2 3 4 5Number of Turns■■■■0 1 2 3 4 50 1 2 3 4 50 1 2 3 4 50 1 2 3 4 5Number of TurnsNumber of TurnsNumber of TurnsNumber of TurnsMaximum operating pressure = 350 bar.Maximum valve leakage at 24 cSt = 0,4 cc/min.Because needle valves are non-compensating devices, the fixed orifice size will regulate flow throughthe valve in proportion to the square root of the pressure differential across ports 1 and 2.The sharp edged orifice design minimizes flow variations due to viscosity changes.OPTION ORDERING INFORMATIONNC ✱✱ – ✱ C ✱MaximumNominal Version Control** Cracking Pressure Seal MaterialOrificeReverse Flow CheckNCBB* 4,0 mm dia. B High Capacity L Standard Screw A* 0,3 bar N Buna-NAdjustmentNCCB 4,8 mm dia. C Low Capacity B* 1,0 bar V VitonNCCC 2,3 mm dia.H CalibratedNCCD 1,5 mm dia. D Low Capacity Handknob with C 2,0 barDetent LockNCEB 6,3 mm dia. D* 3,5 barNCEC 3,2 mm dia. K Handknobwith Lock KnobE* 5,0 barNCFB 9,7 mm dia.NCFC 7,1 mm dia.* Cracking Pressure RangesNCGB 14,2 mm dia.NCGC 9,6 mm dia.A, B, D, and E arenot available for NCBB,T-162A cavity.** See page 178for informationon Control OptionsVisit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.Consult the <strong>Sun</strong> websitefor our most recent andcomplete informationon the full CorrosionResistant line of products.82 Int’l Shortcut <strong>Catalog</strong>ue #999-901-312
Flow Control ValvesFIXED ORIFICE, NON-PRESSURE COMPENSATED, WITHREVERSE FLOW CHECK2bcLocatingShoulder1FreeFlowInlet21Restricted Flow InletPerformance CurvesaNominalCapacityTypicalCartridgeModel CodeCNAC CNCC CNEC CNGC CNICMaximum Reverse Free Flow Pressure DropCartridge DimensionsCavity a b cInstallationTorque(Nm)30 L/min. CNAC – XCN T - 162A 31,0 19,1 20,8 35 - 4060 L/min. CNCC – XCN T - 13A 35,1 22,2 19,1 45 - 50120 L/min. CNEC – XCN T-5A 41,1 28,6 17,5 60 - 70240 L/min. CNGC – XCN T - 16A 62,0 31,8 24,6 200 - 215480 L/min. CNIC – XCN T-18A 79,5 41,3 30,2 465 - 5003030303030P = bar20P = bar20P = bar2010 10XEN10XEN10XEN10XENXCNXCNXCNXCNXCNP = bar20P = bar200 10 20 30 40Flow = L/min.■■■0 20 40 60 80 0 30 60 90 120Flow = L/min.Flow = L/min.0 80 160 240 320 0 160 320 480 640Flow = L/min.Flow = L/min.Maximum operating pressure = 350 bar.There are essentially check valves with bypass orifices. The flow path matches <strong>Sun</strong>’s flow controls andcan be used in any flow control manifolds. Valves with the opposite direction of flow can be foundunder check valves with bypass orifice.Because needle valves are non-compensating devices, the fixed orifice size will regulate flow throughthe valve in proportion to the square root of the pressure differential across ports 1 and 2.OPTION ORDERING INFORMATIONCN ✱ C – X ✱ ✱NominalCapacityControl Cracking Pressure Seal MaterialA 30 L/min. X Not Adjustable A* 0,3 bar N Buna-NB* 1,0 bar V VitonC 60 L/min. C* 2,0 barD* 3,5 barE 120 L/min. E* 5,0 barF* 7,0 barG 240 L/min. Z* 0,7 barCNAC available inI 480 L/min. A, C, E Cracking Pressures Only* Customer specifiedeffective orifice diameterstamped on hex.Orifice Ranges:CNAC: 0,4 - 1,6 mm.CNCC: 0,4 - 3,89 mm.CNEC: 0,4 - 3,42 mm.CNGC: 0,4 - 5,54 mm.CNIC: 0,4 - 5,54 mm.Consult the <strong>Sun</strong> website forour most recent and completeinformation on the full CorrosionResistant line of products.Visit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.Int’l Shortcut <strong>Catalog</strong>ue #999-901-312 83
- Page 1 and 2:
Over 35 New Products in this Catalo
- Page 3 and 4:
ContentsModel Codes printed in Red
- Page 5 and 6:
Relief Cartridge ValvesCartridge Ty
- Page 7 and 8:
Relief ValvesDIRECT ACTING AND DIRE
- Page 9 and 10:
Relief ValvesDIRECT ACTING, PILOT C
- Page 11 and 12:
Relief ValvesPILOT OPERATED, BALANC
- Page 13 and 14:
Relief ValvesPILOT OPERATED, BALANC
- Page 15 and 16:
Relief Valves, Electro-Proportional
- Page 17 and 18:
Relief Valves, Electro-Proportional
- Page 19 and 20:
Relief ValvesPILOT OPERATED, BALANC
- Page 21 and 22:
Relief ValvesBYPASS COMPENSATOR WIT
- Page 23 and 24:
Relief Valves, Electro-Proportional
- Page 25 and 26:
Sequence Cartridge ValvesCartridge
- Page 27 and 28:
Sequence ValvesDIRECT ACTING WITH R
- Page 29 and 30:
Sequence ValvesAIR CONTROLLED, PILO
- Page 31 and 32: Sequence Valves, Electro-Proportion
- Page 33 and 34: Reducing and Reducing/RelievingCart
- Page 35 and 36: Reducing ValvesPILOT OPERATED, AIR
- Page 37 and 38: Reducing/Relieving ValvesPILOT OPER
- Page 39 and 40: Reducing/Relieving ValvesDIRECT ACT
- Page 41 and 42: Reducing/Relieving ValvesPILOT OPER
- Page 43 and 44: Reducing/Relieving Valves, Electro-
- Page 45 and 46: Reducing/Relieving Valves, Electro-
- Page 47 and 48: Pilot-to-Open CheckCartridge Valves
- Page 49 and 50: Pilot-to-Open Check ValvesATMOSPHER
- Page 51 and 52: Counterbalance Cartridge ValvesCart
- Page 53 and 54: Series 2 Series 3 Series 4Pilot Rat
- Page 55 and 56: Counterbalance ValvesNON-VENTED, ST
- Page 57 and 58: Counterbalance ValvesNON-VENTED, SE
- Page 59 and 60: Counterbalance ValvesNON-VENTED, RE
- Page 61 and 62: Counterbalance ValvesVENTED, 280 BA
- Page 63 and 64: Load Control:Load Reactive Cartridg
- Page 65 and 66: Load Control: Load Reactive ValvesN
- Page 67 and 68: Load Control: Load Reactive ValvesV
- Page 69 and 70: Load Control:Balanced Cartridge Val
- Page 71 and 72: Load Control: BalancedVENTED, NON-R
- Page 73 and 74: Check Cartridge ValvesCartridge Typ
- Page 75 and 76: Check ValvesFREE FLOW, SIDE-TO-NOSE
- Page 77 and 78: Check ValvesFREE FLOW, SIDE-TO-NOSE
- Page 79 and 80: Flow Control Valves2Cartridge TypeP
- Page 81: Flow Control ValvesFULLY ADJUSTABLE
- Page 85 and 86: Flow Control ValvesFIXED ORIFICE, P
- Page 87 and 88: Flow Control ValvesFIXED ORIFICE, B
- Page 89 and 90: Flow Control ValvesVENTABLE, FIXED
- Page 91 and 92: Flow Control Valves, Electro-Propor
- Page 93 and 94: Flow Divider / CombinerCartridge Va
- Page 95 and 96: Flow Divider / Combiner ValvesDIVID
- Page 97 and 98: Flow Divider / Combiner ValvesDIVID
- Page 99 and 100: Logic ElementsCartridge Type4421213
- Page 101 and 102: Logic ElementsBALANCED POPPET, NORM
- Page 103 and 104: Logic ElementsBALANCED POPPET, NORM
- Page 105 and 106: Logic ElementsBALANCED POPPET, NORM
- Page 107 and 108: Logic ElementsBALANCED POPPET, NORM
- Page 109 and 110: Logic ElementsUNBALANCED POPPET, VE
- Page 111 and 112: Logic ElementsUNBALANCED POPPET, PI
- Page 113 and 114: Logic ElementsNORMALLY CLOSED, MODU
- Page 115 and 116: Logic ElementsBI-DIRECTIONAL, MODUL
- Page 117 and 118: Directional Cartridge Valves123Cart
- Page 119 and 120: Directional Valves2-WAY AND 3-WAY,
- Page 121 and 122: Directional Valves2-WAY AND 3-WAY D
- Page 123 and 124: Directional Valves2-WAY AND 3-WAY,
- Page 125 and 126: Directional Valves3-WAY, 2-POSITION
- Page 127 and 128: Directional Valves2-WAY POPPET, WIT
- Page 129 and 130: Directional Valves3-POSITION, 4-WAY
- Page 131 and 132: Solenoid Operated Cartridge ValvesC
- Page 133 and 134:
Solenoid Operated Cartridge Valves2
- Page 135 and 136:
Solenoid Operated Cartridge Valves3
- Page 137 and 138:
Solenoid Operated Cartridge Valves3
- Page 139 and 140:
Solenoid Operated Cartridge Valves4
- Page 141 and 142:
Pilot Control ValvesCartridge TypeP
- Page 143 and 144:
Pilot Control ValvesDIRECT ACTING,
- Page 145 and 146:
Pilot Control ValvesFLOW CONTROL, F
- Page 147 and 148:
Pilot Control Valves2-WAY, HYDRAULI
- Page 149 and 150:
Pilot Control Valves2-WAY, AIR OPER
- Page 151 and 152:
Pilot Control Valves3-WAY, 2-POSITI
- Page 153 and 154:
Pilot Control Valves3-WAY, 2-POSITI
- Page 155 and 156:
Shuttle ValvesCartridge TypePage121
- Page 157 and 158:
Shuttle ValvesBACK-TO-BACK CHECK/SH
- Page 159 and 160:
Shuttle ValvesBACK-TO-BACK CHECK/SH
- Page 161 and 162:
Shuttle ValvesHIGH SIDE, 3-POSITION
- Page 163 and 164:
Circuit SaversCartridge TypePage2Fi
- Page 165 and 166:
Circuit SaversAIR BLEED AND START-U
- Page 167 and 168:
Circuit SaversCHECK, PILOT-TO-CLOSE
- Page 169 and 170:
Circuit SaversACCUMULATOR SENSE, PU
- Page 171 and 172:
Hybrid Relief ValvesCartridge TypeP
- Page 173 and 174:
Hybrid ValvesDIRECT ACTING RELIEF,
- Page 175 and 176:
Hybrid ValvesPILOT OPERATED, BALANC
- Page 177 and 178:
General InformationPageCartridge Co
- Page 179 and 180:
Cartridge Control KitsService Kit N
- Page 181 and 182:
Cartridge Control KitsService KitNu
- Page 183 and 184:
Cavity PlugsIt is sometimes desirab
- Page 185 and 186:
Cavity PlugsPlugs for Six Port Cavi
- Page 187:
Sun Coil Options for Solenoids (Met
- Page 191 and 192:
Sun Coil 790-***** Part Numbering S
- Page 193 and 194:
Sun Model Code SystemSun cartridges
- Page 195 and 196:
Model Code IndexModel Code Cavity P
- Page 197 and 198:
Model Code IndexModel Code Cavity P
- Page 199 and 200:
WarrantyWARRANTY INFORMATION,PERFOR
- Page 201:
MexicoCOUNTRYDISTRIBUTORComponentes