Directional Valves2-WAY POPPET, WITH INTEGRAL T-8A CONTROL CAVITY,CONTROL PORT 2 TO PORT 1bcLocatingShoulderT-8A21The -8 control option allows the pilot control valve to be incorporated directlyinto the end of the cartridge via the T-8A cavity. These pilot controlcartridges are sold separately and include electro-proportional, solenoid, airpilot, and hydraulic pilot operation. See Pilot Control Cartridges on page 141.a2Port1PortCapacityTypicalCartridgeModel CodeCartridge DimensionsCavity a b cInstallationTorque(Nm)60 L/min. DFCB – 8DN T-13A 35,1 22,2 19,1 45 - 50120 L/min. DFDB – 8DN T - 5A 41,1 28,6 17,5 60 - 70240 L/min. DFEB – 8DN T-16A 62,0 31,8 24,6 200 - 215Performance CurvesDFCB-8 DFDB-8 DFEB-8Pressure vs. Flow with T-8A Pilot Stage Installed, Port 1 to 2888P = bar642P = bar642P = bar642020 40 60Flow = L/min.025 50 75 100Flow = L/min.125050 100 150 200Flow = L/min.250Pressure vs. Flow with T-8A Pilot Stage Installed, Port 2 to 1888P = bar642P = bar642P = bar642020 40 60 0 25 50 75 100 125Flow = L/min.Flow = L/min.050 100 150 200Flow = L/min.250■■■Maximum operating pressure = 350 bar.Maximum main stage valve leakage at 24 cSt = 0,6 cc/min. at 350 bar (for complete assembly, portvalve leakage must be considered).The main stage valve should first be installed to the correct torque value followed by the T-8A pilotcontrol section into the main stage valve to its required torque value.OPTION ORDERING INFORMATIONDF ✱ B – 8 D ✱NominalCapacityControl Cracking Pressure Seal MaterialC 60 L/min. 8 T-8A cavity in hex body D 3,5 bar N Buna-Nfor pilot operationD 120 L/min. V VitonPilot valve to beE 240 L/min. ordered separatelyOptions are:• Solenoid Pilot• Air Pilot• Hydraulic Pilot• Manual ControlVisit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.128 Int’l Shortcut <strong>Catalog</strong>ue #999-901-312
Directional Valves3-POSITION, 4-WAY, PILOT-TO-SHIFTBPAbPilotPort65PilotPortPort4Port3Port2Tank Port1Performance CurvescaLocatingShoulder2 46 53 1NominalCapacityTypicalCartridgeModel CodeCartridge DimensionsCavity a b cInstallationTorque(Nm)40 L/min. DCCC – XCN T-61A 85,1 22,2 50,0 45 - 5080 L/min. DCDC – XCN T - 62A 92,2 28,6 58,7 60 - 70160 L/min. DCEC – XCN T-63A 114,6 31,8 72,1 200 - 215320 L/min. DCFC – XCN T - 64A 140,0 41,3 91,2 465 - 500DCCC DCDC DCEC DCFCP = barP = bar20151050400300200100■Maximum operating pressure = 350 bar.■Maximum valve leakage at 24 cSt = 30 cc/min. at 70 bar.■Minimum pilot pressure required to shift valve = DCCC: 12 bar, DCDC: 10,5 bar, DCEC, DCFC: 9 bar.■Pilot volume displacement = DCCC: 0,33 cc,; DCDC: 0,98 cc,; DCEC: 2,8 cc,; DCFC: 6,9 cc.■All ports will accept 350 bar, including the x and y pilot ports (port 5 and port 6).■The pilot ports, 5 and 6 are positively sealed from the work ports.■The reason for the different capacities, or performance limits, for the different spool configurations are flow forces. Flowforces are proportional to flow and pressure drop. Typically, they resist the opening of a passage. Spool configurations thatopen passages as they spring centre are the most susceptible. If the flow forces due to the flow and pressure conditionsexceed the centring spring force the valve may not shift completely. Higher flows may be used at lower pressures.NominalCapacityDC ✱ C – X ✱ ✱Control Spool Configuration Spool Configuration Seal Material666662C 40 L/min. X Standard Pilot A A to T CentreR Regen CentreN Buna-ND 80 L/min.E 160 L/min.F 320 L/min.10 20 30Flow = L/min.BWC,A,YH,R,T,X400 20 40 60 80Flow = L/min.NP3 to A2P3 to B4B4 to T1A2 to T1P = barP = bar2015105P3 to B4B4 to T1P3 to B4A2 to T10 20 40 60 800 40 80 120 160Flow = L/min.Flow = L/min.Flow Capacity vs. System Pressure with 12 bar Pilot Signal4003002001000 30 60 90 120Flow = L/min.OPTION ORDERING INFORMATIONA,CH,TB B to T CentreC Blocked CentreH Open CentreN P to A andB to T CentreTypical Pressure DropNYXB,WR3232323234141414141P = barP = bar201510540030020010055555YCWN,R,XH,TB4 to T1A,B0 80 160 240 320Flow = L/min.T Tandem CentreW A and B Bleedto T CentreX P to B andA to T CentreY A and Bto T CentreP3 to B4P3 to A2A2 to T166666P = barP = bar2323232323201510414141414150B4 to T1P3 to B4P3 to A2A2 to T180 160 240 320Flow = L/min.400B,H,R,T Y300A,W,XN200100C0 80 160 320 480Flow = L/min.55555V VitonVisit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.Int’l Shortcut <strong>Catalog</strong>ue #999-901-312 129
- Page 1 and 2:
Over 35 New Products in this Catalo
- Page 3 and 4:
ContentsModel Codes printed in Red
- Page 5 and 6:
Relief Cartridge ValvesCartridge Ty
- Page 7 and 8:
Relief ValvesDIRECT ACTING AND DIRE
- Page 9 and 10:
Relief ValvesDIRECT ACTING, PILOT C
- Page 11 and 12:
Relief ValvesPILOT OPERATED, BALANC
- Page 13 and 14:
Relief ValvesPILOT OPERATED, BALANC
- Page 15 and 16:
Relief Valves, Electro-Proportional
- Page 17 and 18:
Relief Valves, Electro-Proportional
- Page 19 and 20:
Relief ValvesPILOT OPERATED, BALANC
- Page 21 and 22:
Relief ValvesBYPASS COMPENSATOR WIT
- Page 23 and 24:
Relief Valves, Electro-Proportional
- Page 25 and 26:
Sequence Cartridge ValvesCartridge
- Page 27 and 28:
Sequence ValvesDIRECT ACTING WITH R
- Page 29 and 30:
Sequence ValvesAIR CONTROLLED, PILO
- Page 31 and 32:
Sequence Valves, Electro-Proportion
- Page 33 and 34:
Reducing and Reducing/RelievingCart
- Page 35 and 36:
Reducing ValvesPILOT OPERATED, AIR
- Page 37 and 38:
Reducing/Relieving ValvesPILOT OPER
- Page 39 and 40:
Reducing/Relieving ValvesDIRECT ACT
- Page 41 and 42:
Reducing/Relieving ValvesPILOT OPER
- Page 43 and 44:
Reducing/Relieving Valves, Electro-
- Page 45 and 46:
Reducing/Relieving Valves, Electro-
- Page 47 and 48:
Pilot-to-Open CheckCartridge Valves
- Page 49 and 50:
Pilot-to-Open Check ValvesATMOSPHER
- Page 51 and 52:
Counterbalance Cartridge ValvesCart
- Page 53 and 54:
Series 2 Series 3 Series 4Pilot Rat
- Page 55 and 56:
Counterbalance ValvesNON-VENTED, ST
- Page 57 and 58:
Counterbalance ValvesNON-VENTED, SE
- Page 59 and 60:
Counterbalance ValvesNON-VENTED, RE
- Page 61 and 62:
Counterbalance ValvesVENTED, 280 BA
- Page 63 and 64:
Load Control:Load Reactive Cartridg
- Page 65 and 66:
Load Control: Load Reactive ValvesN
- Page 67 and 68:
Load Control: Load Reactive ValvesV
- Page 69 and 70:
Load Control:Balanced Cartridge Val
- Page 71 and 72:
Load Control: BalancedVENTED, NON-R
- Page 73 and 74:
Check Cartridge ValvesCartridge Typ
- Page 75 and 76:
Check ValvesFREE FLOW, SIDE-TO-NOSE
- Page 77 and 78: Check ValvesFREE FLOW, SIDE-TO-NOSE
- Page 79 and 80: Flow Control Valves2Cartridge TypeP
- Page 81 and 82: Flow Control ValvesFULLY ADJUSTABLE
- Page 83 and 84: Flow Control ValvesFIXED ORIFICE, N
- Page 85 and 86: Flow Control ValvesFIXED ORIFICE, P
- Page 87 and 88: Flow Control ValvesFIXED ORIFICE, B
- Page 89 and 90: Flow Control ValvesVENTABLE, FIXED
- Page 91 and 92: Flow Control Valves, Electro-Propor
- Page 93 and 94: Flow Divider / CombinerCartridge Va
- Page 95 and 96: Flow Divider / Combiner ValvesDIVID
- Page 97 and 98: Flow Divider / Combiner ValvesDIVID
- Page 99 and 100: Logic ElementsCartridge Type4421213
- Page 101 and 102: Logic ElementsBALANCED POPPET, NORM
- Page 103 and 104: Logic ElementsBALANCED POPPET, NORM
- Page 105 and 106: Logic ElementsBALANCED POPPET, NORM
- Page 107 and 108: Logic ElementsBALANCED POPPET, NORM
- Page 109 and 110: Logic ElementsUNBALANCED POPPET, VE
- Page 111 and 112: Logic ElementsUNBALANCED POPPET, PI
- Page 113 and 114: Logic ElementsNORMALLY CLOSED, MODU
- Page 115 and 116: Logic ElementsBI-DIRECTIONAL, MODUL
- Page 117 and 118: Directional Cartridge Valves123Cart
- Page 119 and 120: Directional Valves2-WAY AND 3-WAY,
- Page 121 and 122: Directional Valves2-WAY AND 3-WAY D
- Page 123 and 124: Directional Valves2-WAY AND 3-WAY,
- Page 125 and 126: Directional Valves3-WAY, 2-POSITION
- Page 127: Directional Valves2-WAY POPPET, WIT
- Page 131 and 132: Solenoid Operated Cartridge ValvesC
- Page 133 and 134: Solenoid Operated Cartridge Valves2
- Page 135 and 136: Solenoid Operated Cartridge Valves3
- Page 137 and 138: Solenoid Operated Cartridge Valves3
- Page 139 and 140: Solenoid Operated Cartridge Valves4
- Page 141 and 142: Pilot Control ValvesCartridge TypeP
- Page 143 and 144: Pilot Control ValvesDIRECT ACTING,
- Page 145 and 146: Pilot Control ValvesFLOW CONTROL, F
- Page 147 and 148: Pilot Control Valves2-WAY, HYDRAULI
- Page 149 and 150: Pilot Control Valves2-WAY, AIR OPER
- Page 151 and 152: Pilot Control Valves3-WAY, 2-POSITI
- Page 153 and 154: Pilot Control Valves3-WAY, 2-POSITI
- Page 155 and 156: Shuttle ValvesCartridge TypePage121
- Page 157 and 158: Shuttle ValvesBACK-TO-BACK CHECK/SH
- Page 159 and 160: Shuttle ValvesBACK-TO-BACK CHECK/SH
- Page 161 and 162: Shuttle ValvesHIGH SIDE, 3-POSITION
- Page 163 and 164: Circuit SaversCartridge TypePage2Fi
- Page 165 and 166: Circuit SaversAIR BLEED AND START-U
- Page 167 and 168: Circuit SaversCHECK, PILOT-TO-CLOSE
- Page 169 and 170: Circuit SaversACCUMULATOR SENSE, PU
- Page 171 and 172: Hybrid Relief ValvesCartridge TypeP
- Page 173 and 174: Hybrid ValvesDIRECT ACTING RELIEF,
- Page 175 and 176: Hybrid ValvesPILOT OPERATED, BALANC
- Page 177 and 178: General InformationPageCartridge Co
- Page 179 and 180:
Cartridge Control KitsService Kit N
- Page 181 and 182:
Cartridge Control KitsService KitNu
- Page 183 and 184:
Cavity PlugsIt is sometimes desirab
- Page 185 and 186:
Cavity PlugsPlugs for Six Port Cavi
- Page 187:
Sun Coil Options for Solenoids (Met
- Page 191 and 192:
Sun Coil 790-***** Part Numbering S
- Page 193 and 194:
Sun Model Code SystemSun cartridges
- Page 195 and 196:
Model Code IndexModel Code Cavity P
- Page 197 and 198:
Model Code IndexModel Code Cavity P
- Page 199 and 200:
WarrantyWARRANTY INFORMATION,PERFOR
- Page 201:
MexicoCOUNTRYDISTRIBUTORComponentes