Relief ValvesPILOT OPERATED, BALANCED PISTON, VENTABLEFull Adjustment 5 Turns+ -2 13bcPerformance CurvesRVBA RVCA RVEA RVGA RVIAP = bar■■■■■■■■3Vent2Outlet350300250200150100500Inlet 1a10 20 30 40Flow = L/min.LocatingShoulder50P = bar350300CapacityTypicalCartridgeModel CodeMaximum operating pressure = 350 bar.Maximum valve leakage at 24 cSt = RVBA, RVCA: 30 cc/min. at 70 bar; RVEA: 50 cc/min. at 70 bar;RVGA: 65 cc/min. at 70 bar; RVIA: 80 cc/min. at 70 bar.Typical response time 10 ms.Control pilot flow = RVBA, RVCA: 0,11 to 0,16 L/min.; RVEA: 0,16 to 0,25 L/min.; RVGA, RVIA: 0,25 to 0,33 L/min.Factory pressure setting established at 15 L/min.A remote pilot relief on port 3 (vent) will control the valve below its own setting.Will accept maximum pressure at port 2; suitable for use in cross-port relief circuits. If used in cross-port relief circuits, considerspool leakage.Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.RV ✱ A – ✱ ✱ ✱NominalCapacityControl** Adjustment Range Seal MaterialB 30 L/min. L Standard Screw RVBA only: N Buna-NAdjustmentA 5 - 210 barC 60 L/min. Standard set at 70 bar V VitonC*Tamper ResistantB 5 - 105 barE 120 L/min. Factory Set Standard set at 70 bar Consult the <strong>Sun</strong> website forC 5 - 420 barour most recent and completeG 240 L/min. K Handknob Standard set at 70 bar information on the full Corrosionwith Lock Knob N 5 - 55 bar Resistant line of products.I 480 L/min. Standard set at 28 barRVCA, RVEA only: Q 5 - 25 barO Handknob withStandard set at 14 barPanel MountW 5 - 315 barStandard set at 70 bar*Special setting required.Specify at time of order.Cavity a bRVCA, RVEA, RVGA,RVIA only:A 7 - 210 barStandard set at 70 barB 3,5 - 105 barStandard set at 70 barCartridge Dimensions** See page 178 C 10 - 420 bar Adjustment Ranges (Continued)for information Standard set at 70 bar RVEA, RVIA only:on Control Options D 1,7 - 55 bar N 4 - 55 barStandard set at 28 bar Standard set at 28 barE 1,7 - 28 barCustomer specified Standard set at 14 bar RVEA only:special setting W 10 - 315 bar Q 4 - 28 barstamped on hex. Standard set at 70 bar Standard set at 14 barVisit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.cL C K OInstallationTorque(Nm)30 L/min. RVBA – LAN T - 163A 31,0 19,1 64,8 66,8 70,4 71,0 35 - 4060 L/min. RVCA – LAN T - 11A 35,1 22,2 63,5 67,3 70,0 70,0 45 - 50120 L/min. RVEA – LAN T-2A 34,8 28,6 71,4 73,2 77,7 — 60 - 70240 L/min. RVGA – LAN T - 17A 46,0 31,8 83,3 84,1 89,7 — 200 - 215480 L/min. RVIA – LAN T-19A 63,5 41,3 100,0 103,9 106,4 — 465 - 500250200150100500 25 50 75 100Flow = L/min.OPTION ORDERING INFORMATIONP = bar350300250200150100500Typical Pressure Rise50 100 150Flow = L/min.200P = bar350300250200150100500100 200 300Flow = L/min.400P = bar350300250200150100500200 400 600Flow = L/min.80018 Int’l Shortcut <strong>Catalog</strong>ue #999-901-312
Relief ValvesPILOT OPERATED, BALANCED POPPET, VENTABLEFull Adjustment 5 Turns+ -2 13bc3Vent2OutletInlet 1Performance CurvesRVCSP = barP = bar35030025020015010050201510500aLocatingShoulder20 40 60 80Flow = L/min.A,C,WB,Q,N20 40 60Flow = L/min.CapacityTypicalCartridgeModel Code■ Maximum operating pressure = 350 bar.■ Maximum valve leakage at 90% reseat = RVCS: 2 cc/min at 70 bar.; RVES, RVGS, RVIS: 0,7 cc/min at 70 bar.■ Typical response 2 ms.■ Control pilot flow = RVCS: 0,11 to 0,16 L/min.; RVES, RVIS, RVGS: 0,25 to 0,33 L/min.■ Factory pressure setting established at 15 L/min.■ Will accept maximum pressure at port 2; suitable for use in cross-port relief circuits.■ A remote pilot relief on port 3 (vent) will control the valve below its own setting.■ Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.RV ✱ S – ✱ ✱ ✱NominalCapacityControl** Adjustment Range Seal MaterialC 60 L/min. C*Tamper Resistant A 7 - 210 bar N Buna-NFactory SetStandard set at 70 barE 95 L/min. V VitonK Handknob B 3,5 - 105 barG 200 L/min. with Lock Knob Standard set at 70 barI 480 L/min. L Standard Screw C 10,5 - 420 barAdjustmentStandard set at 70 bar* Special setting required. N 4 - 55 barSpecify at time of order.Standard set at 25 bar** See page 178 Q 4 - 25 barfor informationStandard set at 14 baron Control OptionsW 10,5 - 315 barCustomer specified specialStandard set at 70 barsetting stamped on hex.Cartridge DimensionscCavity a bL C KVisit www.sunhydraulics.com for current list pricing and complete technical information on all <strong>Sun</strong> products.InstallationTorque(Nm)60 L/min. RVCS – LAN T-11A 34,8 22,2 63,2 67,3 70,0 45 - 5095 L/min. RVES – LAN T - 2A 34,8 28,6 71,4 73,2 77,7 60 - 70200 L/min. RVGS – LAN T-17A 46,0 31,8 83,3 84,1 89,7 200 - 215480 L/min. RVIS – LAN T - 19A 63,5 41,3 99,8 103,1 106,4 465 - 500RVES10080P = barP = bar350350300 30025020015010050OPTION ORDERING INFORMATION2015050 100 150Flow = L/min.RVGSTypical Pressure Rise20010C,W5B,N,Q A0 25 50 75 100 125 150Flow = L/min.P = barP = bar25020015010050Vented Pressure020151050100 200 300Flow = L/min.C,W,AB,Q,N80 160 240Flow = L/min.RVIS400320P = barP = bar35030025020015010050201510500A100 200 300 400Flow = L/min.BQ & NC & W100 200 300 400Flow = L/min.500500Int’l Shortcut <strong>Catalog</strong>ue #999-901-312 19
- Page 1 and 2: Over 35 New Products in this Catalo
- Page 3 and 4: ContentsModel Codes printed in Red
- Page 5 and 6: Relief Cartridge ValvesCartridge Ty
- Page 7 and 8: Relief ValvesDIRECT ACTING AND DIRE
- Page 9 and 10: Relief ValvesDIRECT ACTING, PILOT C
- Page 11 and 12: Relief ValvesPILOT OPERATED, BALANC
- Page 13 and 14: Relief ValvesPILOT OPERATED, BALANC
- Page 15 and 16: Relief Valves, Electro-Proportional
- Page 17: Relief Valves, Electro-Proportional
- Page 21 and 22: Relief ValvesBYPASS COMPENSATOR WIT
- Page 23 and 24: Relief Valves, Electro-Proportional
- Page 25 and 26: Sequence Cartridge ValvesCartridge
- Page 27 and 28: Sequence ValvesDIRECT ACTING WITH R
- Page 29 and 30: Sequence ValvesAIR CONTROLLED, PILO
- Page 31 and 32: Sequence Valves, Electro-Proportion
- Page 33 and 34: Reducing and Reducing/RelievingCart
- Page 35 and 36: Reducing ValvesPILOT OPERATED, AIR
- Page 37 and 38: Reducing/Relieving ValvesPILOT OPER
- Page 39 and 40: Reducing/Relieving ValvesDIRECT ACT
- Page 41 and 42: Reducing/Relieving ValvesPILOT OPER
- Page 43 and 44: Reducing/Relieving Valves, Electro-
- Page 45 and 46: Reducing/Relieving Valves, Electro-
- Page 47 and 48: Pilot-to-Open CheckCartridge Valves
- Page 49 and 50: Pilot-to-Open Check ValvesATMOSPHER
- Page 51 and 52: Counterbalance Cartridge ValvesCart
- Page 53 and 54: Series 2 Series 3 Series 4Pilot Rat
- Page 55 and 56: Counterbalance ValvesNON-VENTED, ST
- Page 57 and 58: Counterbalance ValvesNON-VENTED, SE
- Page 59 and 60: Counterbalance ValvesNON-VENTED, RE
- Page 61 and 62: Counterbalance ValvesVENTED, 280 BA
- Page 63 and 64: Load Control:Load Reactive Cartridg
- Page 65 and 66: Load Control: Load Reactive ValvesN
- Page 67 and 68: Load Control: Load Reactive ValvesV
- Page 69 and 70:
Load Control:Balanced Cartridge Val
- Page 71 and 72:
Load Control: BalancedVENTED, NON-R
- Page 73 and 74:
Check Cartridge ValvesCartridge Typ
- Page 75 and 76:
Check ValvesFREE FLOW, SIDE-TO-NOSE
- Page 77 and 78:
Check ValvesFREE FLOW, SIDE-TO-NOSE
- Page 79 and 80:
Flow Control Valves2Cartridge TypeP
- Page 81 and 82:
Flow Control ValvesFULLY ADJUSTABLE
- Page 83 and 84:
Flow Control ValvesFIXED ORIFICE, N
- Page 85 and 86:
Flow Control ValvesFIXED ORIFICE, P
- Page 87 and 88:
Flow Control ValvesFIXED ORIFICE, B
- Page 89 and 90:
Flow Control ValvesVENTABLE, FIXED
- Page 91 and 92:
Flow Control Valves, Electro-Propor
- Page 93 and 94:
Flow Divider / CombinerCartridge Va
- Page 95 and 96:
Flow Divider / Combiner ValvesDIVID
- Page 97 and 98:
Flow Divider / Combiner ValvesDIVID
- Page 99 and 100:
Logic ElementsCartridge Type4421213
- Page 101 and 102:
Logic ElementsBALANCED POPPET, NORM
- Page 103 and 104:
Logic ElementsBALANCED POPPET, NORM
- Page 105 and 106:
Logic ElementsBALANCED POPPET, NORM
- Page 107 and 108:
Logic ElementsBALANCED POPPET, NORM
- Page 109 and 110:
Logic ElementsUNBALANCED POPPET, VE
- Page 111 and 112:
Logic ElementsUNBALANCED POPPET, PI
- Page 113 and 114:
Logic ElementsNORMALLY CLOSED, MODU
- Page 115 and 116:
Logic ElementsBI-DIRECTIONAL, MODUL
- Page 117 and 118:
Directional Cartridge Valves123Cart
- Page 119 and 120:
Directional Valves2-WAY AND 3-WAY,
- Page 121 and 122:
Directional Valves2-WAY AND 3-WAY D
- Page 123 and 124:
Directional Valves2-WAY AND 3-WAY,
- Page 125 and 126:
Directional Valves3-WAY, 2-POSITION
- Page 127 and 128:
Directional Valves2-WAY POPPET, WIT
- Page 129 and 130:
Directional Valves3-POSITION, 4-WAY
- Page 131 and 132:
Solenoid Operated Cartridge ValvesC
- Page 133 and 134:
Solenoid Operated Cartridge Valves2
- Page 135 and 136:
Solenoid Operated Cartridge Valves3
- Page 137 and 138:
Solenoid Operated Cartridge Valves3
- Page 139 and 140:
Solenoid Operated Cartridge Valves4
- Page 141 and 142:
Pilot Control ValvesCartridge TypeP
- Page 143 and 144:
Pilot Control ValvesDIRECT ACTING,
- Page 145 and 146:
Pilot Control ValvesFLOW CONTROL, F
- Page 147 and 148:
Pilot Control Valves2-WAY, HYDRAULI
- Page 149 and 150:
Pilot Control Valves2-WAY, AIR OPER
- Page 151 and 152:
Pilot Control Valves3-WAY, 2-POSITI
- Page 153 and 154:
Pilot Control Valves3-WAY, 2-POSITI
- Page 155 and 156:
Shuttle ValvesCartridge TypePage121
- Page 157 and 158:
Shuttle ValvesBACK-TO-BACK CHECK/SH
- Page 159 and 160:
Shuttle ValvesBACK-TO-BACK CHECK/SH
- Page 161 and 162:
Shuttle ValvesHIGH SIDE, 3-POSITION
- Page 163 and 164:
Circuit SaversCartridge TypePage2Fi
- Page 165 and 166:
Circuit SaversAIR BLEED AND START-U
- Page 167 and 168:
Circuit SaversCHECK, PILOT-TO-CLOSE
- Page 169 and 170:
Circuit SaversACCUMULATOR SENSE, PU
- Page 171 and 172:
Hybrid Relief ValvesCartridge TypeP
- Page 173 and 174:
Hybrid ValvesDIRECT ACTING RELIEF,
- Page 175 and 176:
Hybrid ValvesPILOT OPERATED, BALANC
- Page 177 and 178:
General InformationPageCartridge Co
- Page 179 and 180:
Cartridge Control KitsService Kit N
- Page 181 and 182:
Cartridge Control KitsService KitNu
- Page 183 and 184:
Cavity PlugsIt is sometimes desirab
- Page 185 and 186:
Cavity PlugsPlugs for Six Port Cavi
- Page 187:
Sun Coil Options for Solenoids (Met
- Page 191 and 192:
Sun Coil 790-***** Part Numbering S
- Page 193 and 194:
Sun Model Code SystemSun cartridges
- Page 195 and 196:
Model Code IndexModel Code Cavity P
- Page 197 and 198:
Model Code IndexModel Code Cavity P
- Page 199 and 200:
WarrantyWARRANTY INFORMATION,PERFOR
- Page 201:
MexicoCOUNTRYDISTRIBUTORComponentes