11.07.2015 Views

131 LA UR 03 5862 - National Nuclear Security Administration ...

131 LA UR 03 5862 - National Nuclear Security Administration ...

131 LA UR 03 5862 - National Nuclear Security Administration ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Table 2.2.3-1. Tritium Facilities (TA-16 and TA-21)/Operations DataPARAMETERRadioactive AirEmissions:• TA-16, WETF,Elemental tritium• TA-16, WETF,Tritium in watervapor• TA-21, TSTA,Elemental tritium• TA-21, TSTA,Tritium in watervapor• TA-21, TSFF,Elemental tritium• TA-21, TSFF,Tritium in watervaporUNITSSWEISROD1998 1999 2000 2001 2002OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONSCi/yr 3.0E+2 2.3E+1 2.4E+1 3.9E+1 7.7E+3 3.0E+2Ci/yr 5.0E+2 2.2E+2 1.4E+2 2.2E+2 2.0E+2 1.0E+2Ci/yr 1.0E+2 1.3E+1 1.7E+1 2.5E+1 7.1E+0 4.1E+1Ci/yr 1.0E+2 6.9E+1 4.9E+1 1.5E+2 5.8E+1 4.8E+2Ci/yr 6.4E+2 7.3E+1 9.2E+1 2.5E+2 3.1E+1 2.6E+1Ci/yr 8.6E+2 3.1E+2 3.3E+2 5.1E+2 3.9E+2 5.8E+2NPDES Discharge:Total Discharges MGY 0.3 13.7 8.97 8.6 0.3932 b 13.4000• 05S (SewageTreatment Plant,MGY 0.0 Eliminated1998Eliminated1998Eliminated1998Eliminated1998Eliminated1998aTA-21)• 02A-129 MGY 0.1 13.0 8.83 7.9 0.3902 b 10.8400(TA-21)• <strong>03</strong>A-<strong>03</strong>6 MGY 0.0 Eliminated Eliminated Eliminated Eliminated Eliminateda(TA-21)1997 19971997 1997 1997• <strong>03</strong>A-158 MGY 0.2 0.7 0.14 c 0.7 0.0<strong>03</strong>00 2.5600(TA-21)• 04A-091a(TA-16)MGY 0.0 Eliminated1997Eliminated1997Eliminated1997Eliminated1997Eliminated1997Wastes:Chemical kg/yr 1,700 195 30 10d2,615e5,164LLW m 3 /yr 480 46 47 49 090MLLW m 3 /yr 3 0.10 0 0.01 0.8TRU m 3 /yr 0 00 00 0Mixed TRU m 3 /yr 0 0 00 0 0Number of FTEs 123 f 31 f 28 fWorkers 28 f 24 f 25 f f20abcdefOutfalls eliminated before 1999: 05S (TA-21), <strong>03</strong>A-<strong>03</strong>6 (TA-21), and 04A-091 (TA-16). Consolidation and removal of outfallshas resulted in projected NPDES volumes underestimating actual discharges from the exiting outfalls.Discharge quantity is not considered significantly different from the SWEIS ROD.This outfall only discharged two quarters during CY 1999.During CY 2001, 2,350 kilograms of the chemical waste are from refrigerant replacement at TA-16-450.Over 4,000 kilograms of the chemical waste in CY 2002 are from refrigerant replacement at TA-16-450.The first number shown in the “SWEIS ROD” column is the actual employee count representing CY 1999 (the year theSWEIS ROD was published). The second number shown in the “SWEIS ROD” column is the index number representingCY 1999 (the year the SWEIS ROD was published). The number of employees for 1998 through 2002 operations cannotbe directly compared to numbers projected by the SWEIS ROD. The employee numbers projected by the SWEIS RODrepresent total workforce size and include PT<strong>LA</strong>, JCNNM, and other subcontractor personnel. The number of employeesfor CY 1998 through CY 2002 operations is routinely collected information and represents only UC employees (regularfull-time and part-time). Because the two sets of numbers (SWEIS ROD versus the new index) do not represent the same entity,a direct comparison to numbers projected by the SWEIS ROD (see Section 3.6, Socioeconomics) is not appropriate.However, because this index is going to be used in each subsequent Yearbook, selecting CY 1999 as the base yearestablishes an index that can be compared over the 10-year window represented by the SWEIS ROD.SWEIS Yearbook—2002 2-51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!