9. Connect the plug end of the power cord into outlet.<br />

Redundant power supply installation 3<br />

CAUTION<br />

For the NEBS compliant installation of a <strong>Brocade</strong> NetIron <strong>CES</strong> 2000 or <strong>Brocade</strong> NetIron <strong>CER</strong><br />

2000 Series devices with AC <strong>and</strong> DC system use a ground wire of at least #6 American Wire<br />

Gauge (AWG). The ground wire should have an agency-approved crimped connector (provided<br />

with the chassis) attached to one end, with the other end grounded to either a common bonding<br />

network or an isolated bonding network. The connector must be crimped with the proper tool,<br />

allowing it to be connected to both ground screws on the enclosure. Before crimping the ground<br />

wire into the provided ground lug, insure the bare copper wire has been cleaned <strong>and</strong> antioxidant<br />

is applied to the bare wire.<br />

CAUTION<br />

To insure adequate bonding when attaching the provided P<strong>and</strong>uit LCD6-10AF two-hole ground<br />

lug, a minimum of 20 PSI of torque is required to be applied to the mounting hardware used to<br />

attach the ground lug. Use a star washer to ensure an NEBS compliant connection.<br />

Installing a DC power supply<br />

DANGER<br />

Before beginning the installation, refer to the precautions in “Power precautions” on page 27.<br />

Use the following procedures for DC power supplies in <strong>Brocade</strong> NetIron <strong>CES</strong>, <strong>Brocade</strong> NetIron <strong>CER</strong><br />

2000 series devices.<br />

Follow the steps given below to install an DC power supply.<br />

1. If necessary, remove the power supply locking screws located in the upper left <strong>and</strong> the bottom<br />

right of the device.<br />

2. If the empty power supply bay has a cover plate, remove the two screws near the edges of the<br />

cover plate to unlock the plate, then remove the plate.<br />

3. Remove the DC power supply from its packaging (Figure 23).<br />

<strong>Brocade</strong> NetIron <strong>CES</strong> <strong>and</strong> <strong>Brocade</strong> NetIron <strong>CER</strong> <strong>Devices</strong> <strong>Hardware</strong> Guide 33<br />

53-1002425-03