TABLE 13 LEDs for power <strong>and</strong> fans (located on front of device (Continued))<br />

LED State Meaning<br />

Power supply replacement 5<br />

PS1 (labeled P1) Off Power supply 1 is not installed or is not<br />

providing power.<br />

The LEDs for Fan, PS1 <strong>and</strong> PS2 are located on the right side of the front panel for <strong>Brocade</strong> NetIron<br />

<strong>CES</strong> <strong>and</strong> <strong>Brocade</strong> NetIron <strong>CER</strong> 2024 models (On the <strong>Brocade</strong> NetIron <strong>CES</strong> 2048 <strong>and</strong> <strong>Brocade</strong><br />

NetIron <strong>CER</strong> 2048 models, these LEDs are located on the left side of the front panel).<br />

The software regularly polls the hardware for power status information. You can display the status<br />

information from any management session. In addition, the software automatically generates a<br />

Syslog message <strong>and</strong> SNMP trap if a status change occurs.<br />

Displaying the status of the power supplies<br />

You can display the status of the power supplies by entering the show chassis comm<strong>and</strong> at any<br />

level of the CLI. The display shows whether a power supply is installed in the specified power supply<br />

slot <strong>and</strong> the status of the power supply. If you are not already attached to a terminal or a PC running<br />

terminal emulation, see “PC or terminal attachment” on page 45<br />

<strong>Brocade</strong>> show chassis<br />

*** <strong>Brocade</strong> NetIron <strong>CES</strong> 2048CX ***<br />

Amber Power supply 1 is installed, but not connected<br />

or a fault is detected.<br />

Green Steady Power supply 1 is installed <strong>and</strong> is functioning<br />

normally.<br />

Green Blinking Power supply 1 has input power, but is not<br />

enabled <strong>and</strong> has no output power.<br />

PS2 (labeled P2) Off Power supply 2 is not installed or is not<br />

providing power.<br />

Amber Power supply 2 is installed, but not connected<br />

or a fault is detected.<br />

Green Steady Power supply 2 is installed <strong>and</strong> is functioning<br />

normally.<br />

Green Blinking Power supply 2 has input power, but is not<br />

enabled <strong>and</strong> has no output power.<br />

---POWERS ---<br />

Power 1 ( 3I50 - AC 504W): Installed (OK)<br />

Power 2: not present<br />

Total power budget for system = 504 W<br />

--- FANS ---<br />

Metro fan tray (fan 1): Status = OK, Speed = LOW (50%)<br />

Metro fan tray (fan 2): Status = OK, Speed = LOW (50%)<br />

Metro fan tray (fan 3): Status = OK, Speed = LOW (50%)<br />

Metro fan tray (fan 4): Status = OK, Speed = LOW (50%)<br />

Metro fan tray (fan 5): Status = OK, Speed = LOW (50%)<br />

Metro fan tray (fan 6): Status = OK, Speed = LOW (50%)<br />

--- TEMPERATURE READINGS ---<br />

CPU: Board 32.50C Chip 41.6C<br />

481XG PPCR1: Board 32.50C Chip 43.31C<br />