PC or terminal attachment 3<br />

The software regularly polls the hardware for power status information. You can display the status<br />

information from any management session. In addition, the software automatically generates a<br />

Syslog message <strong>and</strong> SNMP trap if a status change occurs.<br />

PC or terminal attachment<br />

To assign an IP address, you must have access to the Comm<strong>and</strong> Line Interface (CLI). The CLI is a<br />

text-based interface that can be accessed through a direct serial connection to the device <strong>and</strong><br />

through Telnet connections.<br />

You need to assign an IP address using the CLI. You can access the CLI by attaching a serial cable<br />

to the Console port. After you assign an IP address, you can access the system through Telnet or<br />

IronView Network Manager.<br />

Attaching a PC or terminal<br />

Follow the steps given below to attach a management station using the serial port.<br />

1. Connect a PC or terminal to the serial port of the system using a straight-through cable. The<br />

serial port has a male DB-9 connector.<br />

NOTE<br />

You need to run a terminal emulation program on the PC.<br />

2. Open the terminal emulation program <strong>and</strong> set the session parameters as follows:<br />

• Baud: 9600 bps<br />

• Data bits: 8<br />

• Parity: None<br />

• Stop bits: 1<br />

• Flow control: None<br />

When you establish the serial connection to the system, press Enter to display the CLI prompt in the<br />

terminal emulation window. For example:<br />

<strong>Brocade</strong>><br />

If you see this of these prompt, you are now connected to the system <strong>and</strong> can proceed to<br />

“Password assignment” on page 19.<br />

You can customize the prompt by changing the system name. For more information, refer to the<br />

<strong>Brocade</strong> MLX Series <strong>and</strong> NetIron Family Configuration Guide.<br />

If you do not see one of these prompts, follow the instructions given below.<br />

1. Make sure the cable is securely connected to your PC <strong>and</strong> to the <strong>Brocade</strong> system.<br />

2. Check the settings in your terminal emulation program. In addition to the session settings<br />

listed above, make sure the terminal emulation session is running on the same serial port you<br />

attached to the<strong>Brocade</strong> system.<br />

The EIA/TIA 232 serial communication port serves as a connection point for management by a PC<br />

or SNMP workstation.<br />

<strong>Brocade</strong> NetIron <strong>CES</strong> <strong>and</strong> <strong>Brocade</strong> NetIron <strong>CER</strong> <strong>Devices</strong> <strong>Hardware</strong> Guide 45<br />