3<br />

System power<br />

System power<br />

After you complete the physical installation of the system, you can power on the system.<br />

Powering on the system<br />

1. Ensure that all power supplies are fully <strong>and</strong> properly inserted <strong>and</strong> no power supply slots are<br />

uncovered.<br />

CAUTION<br />

Never leave tools inside the device.<br />

2. Remove the power cord from the shipping package.<br />

3. Attach the AC power cable to the AC connector on the rear panel.<br />

4. Insert the power cable plug into a 115V/120V outlet.<br />

NOTE<br />

To turn the system off, simply unplug the power cords.<br />

NOTE<br />

The socket should be installed near the equipment <strong>and</strong> should be easily accessible.<br />

NOTE<br />

If the outlet is not rated 115/120V, stop <strong>and</strong> get the appropriate cable for the outlet.<br />

DANGER<br />

The intra-building ports of the equipment or subassembly is suitable for connection to<br />

intra-building or unexposed wiring or cabling only. The intra-building ports of the equipment or<br />

subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its<br />

wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4<br />

ports as described in GR-1089-CORE, Issue 4) <strong>and</strong> require isolation from the exposed OSP<br />

cabling. The addition of Primary Protectors is not sufficient protection in order to connect these<br />

interfaces metallically to OSP wiring.<br />

DANGER<br />

Before crimping the ground wire into the provided ground lug insure the bare copper wire has<br />

been cleaned <strong>and</strong> antioxidant is applied to the bare wire.<br />

DANGER<br />

To insure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is<br />

required to be applied to the mounting hardware used to attach the ground lug.<br />