12.07.2015 Views

Power Spot 250 User Manual (pdf) - Elation Professional

Power Spot 250 User Manual (pdf) - Elation Professional

Power Spot 250 User Manual (pdf) - Elation Professional

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Power</strong> <strong>Spot</strong> <strong>250</strong>2.3 Connections2.3.1 <strong>Power</strong> supply115v ~ 50/60Hz AC (America’s),Connected load 500W 4.4 A (blind current compensation)or 230V ~ 50Hz AC (EU),Connected load 500W 2.2 A (blind current compensation)Operating voltage is pre-selected at the factory and is not user selectable.Because line voltage may vary from venue to venue, you should be sure yourfixture voltage matches that of the outlet. The voltage requirements for thefixture are clearly printed on the side panel near the power cord.2.3.2 DMX-5123-Pin XLR Input/Output. [+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 12.4 DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used bymost lighting and controller manufactures as a form of communication betweenintelligent fixtures and controllers. A DMX controller sends DMX data instructionsfrom the controller to the fixture. DMX data is sent out as serial data that travels fromfixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMXfixtures (most controllers only have a DATA “OUT” terminals). DMX Linking: DMX is alanguage allowing all makes and models of different manufactures to be linkedtogether and operate from a single controller, as long as all fixtures and thecontroller are DMX compliant. To ensure proper DMX data transmission, whenusing several DMX fixtures try to use the shortest cable path possible. The order inwhich fixtures are connected in a DMX line does not influence the DMX addressing.For example; a fixture assigned a DMX address of 1 may be placed anywhere in aDMX line, at the beginning, at the end, or anywhere in the middle. Therefore, the firstfixture controlled by the controller could be the last fixture in the chain. When a fixtureis assigned a DMX address of 1, the DMX controller knows to send DATA assignedto address 1 to that fixture, no matter where it is located in the DMX chain.2.5 Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation):The POWER SPOT <strong>250</strong> can be controlled via DMX-512 protocol. The POWERSPOT <strong>250</strong> is a 15 channel DMX fixture. The DMX address is set electronically©<strong>Elation</strong> <strong>Professional</strong>s® Los Angeles, Ca. - wwww.<strong>Elation</strong>Lighting.com - Page 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!