Assembly<strong>GEA</strong> <strong>CAIRfricostar</strong>Additional connection for double deck/side by side units• Connect both unit parts at the pre-drilled positions using provided plates.Fig. 5-16: Connectingunit partsParticulars for hygiene units• Clean and seal all internal break point grooves.The sealant is included in the scope of delivery for hygiene units.Fig. 5-17: Break point grooveParticulars for units for outside installationDAMAGE TO THE UNIT!Defective sealing provided on site may result in the ingress of water and subsequentdamage! Seal all parts carefully.Assembly of roofcomponents supplied looseThe roof sheeting above the break point is supplied loose with separated units.• Remove protective film prior to installation.• Install the roof sheeting on site.• The roof sheeting is joined together using clamping strips and supplied metricscrews (M6x16, plastic washers and nuts on both sides)orwith roof hat channel profiles using self-drilling screws (6.3 x 25 with sealingwasher). The joints formed during the above process must be sealed using thesupplied transparent sealing material.Fig. 5-18: Roof sheet28 PR-2006-0019-GB • Subject to modifications • Status 05/2009