Installation<strong>GEA</strong> <strong>CAIRfricostar</strong>NoteThese limit values provideonly basic informationabout the water qualityand do not present anybasis for a guarantee!Description Symbol ValuesHydrogen ion concentration pH 7.5 − 9 < 7> 9Calcium and magnesiumcontentHardness(Ca/Mg)Effects in event ofdeviationCorrosionFouling4 − 8.5 °D > 8.5 FoulingChloride ions Cl – < 50 ppm CorrosionIron ions Fe³ + < 0.5 ppm CorrosionMagnesium ions Mg² + < 0.05 ppm CorrosionCarbon dioxide CO 2 < 10 ppm CorrosionHydrogen sulphate H 2 S < 50 ppb CorrosionOxygen O 2 < 0.1 ppm CorrosionChlorine Cl 2 < 0.5 ppm CorrosionAmmonia NH 3 < 0.5 ppm CorrosionRatio of carbons/sulphates HCO 3 ² - /SO 4 ² - > 1 < 1 Corrosion1/1.78 °D = 1 °Fr with 1 °Fr = 10 g CaCO 3 /m³ppm = parts per million (mg/l)ppb = parts per billion (μg/l)NOTE!The air side corrosion protection of buil-in unit components is provided if the chemicalvalues of pool water do not exceed limit values as defined by VDI 2089 Page 2„Water treatment in swimming pools“ and VDI 19643.6.3.1 Installing air handling components for cooling/heatingDAMAGE TO THE UNIT!When connecting the heat exchanger, counter force must be applied using pliers toprevent damage.The connections to the heat exchanger provided on site must always be tensionfree.Mechanical and static loads must not be applied to the connecting spigots.The heat exchanger must be connected in accordance with the counter flow principle(air and water heat exchanger flow in opposite directions).• Protect the surfaces of the fins in the heat exchanger from damage.• Connect on-site pipe system to the water inlet and outlet. The inlet and outlet coilconnections are marked using adhesive labels.• Insulate pipes on site.Additional information about air handling components with cooling function:• Insulate coil connections and pipes once the installation has been carried out toprevent the formation of condensation water. Condensate water that is formed accumulates in the stainless steel condensate trayand is drained via a drain spigot mounted on the condensate tray.• Install a siphon (See „Connecting siphon and water drains“ on page 37).32 PR-2006-0019-GB • Subject to modifications • Status 05/2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!