System CommandsprilinebuildoutSets or gets the PRI line buildout <strong>for</strong> a T1 interface.Syntaxprilinebuildout getprilinebuildout set prilinebuildout set ParametergetsetDescriptionReturns the current setting.Sets the PRI line buildout. It requires an output“attenuation in dB” or an “attenuation infeet”.0|-7.5|-15|-22.5 Output attenuation values in dB. For internal CSUs.0-133|134-266|267-399|400-533|534-665Output attenuation values in feet. For external CSUs.Feedback Examplesprilinebuildout set -7.5returnsprilinebuildout -7.5CommentsIf you are using an internal CSU, enter the output attenuation in dB. If you areusing an external CSU, enter the output attenuation in feet.See AlsoThe PRI CSU mode <strong>for</strong> a T1 interface is set using the pricsu command onpage 4-180.4 - 183