12.07.2015 Views

Integrator's Reference Manual for Polycom HDX ... - 1 PC Network Inc

Integrator's Reference Manual for Polycom HDX ... - 1 PC Network Inc

Integrator's Reference Manual for Polycom HDX ... - 1 PC Network Inc

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Integrator’s <strong>Reference</strong> <strong>Manual</strong> <strong>for</strong> <strong>Polycom</strong> <strong>HDX</strong> SystemsCeiling TilesThese should be high-quality acoustic tiles, ideally 1”- thick compresseddensecore fiberglass. An added benefit of this kind of ceiling tile is that itworks well with the indirect lighting as specified elsewhere in this section. Toreduce any extraneous noise from leaving or entering the room via the ceilingspace, the ceiling tiles can be blanketed completely from the plenum side, witha minimum of 6”- thick unfaced dense fiberglass batting or mineral rock wool,(the equivalent of R-15 to R-19). Here again, a barrier layer will improve theper<strong>for</strong>mance, but all local building codes must be followed <strong>for</strong> allowablematerials in the various aspects of room acoustic modifications. To make entryand exit from the ceiling space easier, the blanket and barrier do not need torest on the ceiling tiles, but may be suspended above it.Air ConditioningIt is critical that all air-handling equipment (blowers, heat exchangers,solenoid valves, etc.) be located outside the physical meeting room space. Thiswill prevent the noise burden associated with such equipment from affectingthe participants of any meetings held in the room. Location of air-handlingequipment within the ceiling space of a conference room often renders thatroom unusable <strong>for</strong> video or audio-only conferencing.The air vents should be of open construction to eliminate “wind noise” whilethe system is running. These vents normally are specified as “low-velocity”diffusers. The number of air vents within the room should be sufficient tomaintain a consistent temperature throughout the space. All HVAC ducts anddiffusers should be oversized <strong>for</strong> the general application in the space, withminimum 2’ diameter insulated flexible ducts and matching 2’ noisedampening diffusers generally best. All ducts should be installed with gradualbends and curves rather than rigid 90-degree corners. This will minimize“thunder” sounds as the initial air pushes through the ductwork and into theroom.There should be a thermostat to control this specific room systemindependently of the rest of the building, and that control should be locatedwithin the room.Important: Allow an additional 5,000 BTU of cooling capacity <strong>for</strong> a standard“roll-about” singlemonitor VC system with extended in-room peripherals(<strong>PC</strong>, document camera, scan converter, etc.) and a minimum of 10,000 BTU <strong>for</strong>a dual display multimedia presentation system with large screen displays. Forthe com<strong>for</strong>t of the participants, the room must accommodate these heat loads,plus the heat load of a room full of people, with minimal temperature rise.A - 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!