3.19 <strong>AT</strong>+FPHCTO DTE Phase C Response TimeoutRead command<strong>AT</strong>+FPHCTO?The time-out value determines how long the DCE will wait for a commandafter reaching the end of data when transmitting in Phase C. When time-out isreached, the DCE assumes that there are no more pages or documents to send.Write command<strong>AT</strong>+FPHCTO=ReferenceEIA PN-2388Response OKParameterSee write commandParameter 0 – 30 – 255 time-out value in 100ms units.ResponseOKIf error is related to ME functionality:ERRORNoteUsed for Fax class 2 only3.20 <strong>AT</strong>+FREV Identify Product RevisionTest command<strong>AT</strong>+FREV?ReferenceSiemensSends the revision identification to the TAResponseV2.550OKNoteUsed for Fax class 2 only3.21 <strong>AT</strong>+FRH Receive Data Using HDLC FramingExecute command<strong>AT</strong>+FRH=This command causes the TA to receive frames using the HDLC protocol and themodulation defined below. An ERROR response code results if this command isissued while the modem is on-hook.ResponseCONNECTIf error is related to ME functionality:ERRORReferenceTIA/EIA-578Parameter modulation mode3 V21 Ch2 300 bps24 V.27ter 2400 bps48 V.27ter 4800 bps72 V.29 7200 bps96 V.29 9600 bpsNoteUsed for Fax class 1 onlyPage 57 of 207