OKWhen, for example, an SMS is being received and indicated by an unsolicitedresult code (URC), the ME wakes up to full operation.+CMTI: "SM",5 Note that the URC used in this example will appearonly if CMTI=1,1 was configured before. See Chapters5.10 and 8.1.4.After this, you may want to verify the operating status:<strong>AT</strong>+CFUN?+CFUN: 1Indicates that ME has entered full functionality mode.Example 3To stop CYCLIC SLEEP mode and return to full functionality:<strong>AT</strong>+CFUN?+CFUN: 5OK<strong>AT</strong>+CFUN=1OKRemember that this approach is not applicable to the NON-CYCLIC SLEEPmode (since the serial interface is disabled). The NON-CYCLIC SLEEP modeends with the first wake-up event.Example 4To reset and restart the ME:<strong>AT</strong>+CFUN=1,1 or alternatively, <strong>AT</strong>+CFUN=0,1 or 5,1 or 6,1OK^SYSSTARTThe ^SYSSTART URC confirms that the ME has beenrebooted.Note that ^SYSSTART appears only if <strong>AT</strong>+IPR≠0. If theME is in autobaud mode, it is recommended to wait 3 to5 seconds before entering the first <strong>AT</strong> command.Remember to enter the SIM PIN after restart.Page 78 of 207