12.07.2015 Views

FLEX I/O and FLEX Integra

FLEX I/O and FLEX Integra

FLEX I/O and FLEX Integra

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

134 Choosing the Correct Counter Module for Your Application <strong>FLEX</strong> I/O <strong>and</strong> <strong>FLEX</strong> <strong>Integra</strong> Product DataChoosing the Correct Counter Module for Your Application1794-IJ21794-ID2Description: Essentially a tachometer with the capability of reportingfrequency, acceleration, <strong>and</strong> direction. Outputs are activated byalarms. Input devices range from magnetic pickup to flowmeters, toincremental encoders to proximity detectors.This intelligent I/O module is designed to perform high-speedfrequency algorithms. The module provides 2 frequency inputs, 2 gateinputs, <strong>and</strong> 2 outputs. The frequency inputs are capable of acceptingfrequencies up to 32KHz. The module accepts <strong>and</strong> returns binary data.The 1794-IJ2 measures frequency over a user-specified time interval. Afrequency calculation can start before the time interval has elapsed, ifa user-specified number of frequency input pulses have occurred.The module’s primary target is high-speed, accurate frequencymeasurement. As such, a high-speed internal clock is synchronizedwith the frequency input to count over a user-selected sampling timeor a user-defined number of frequency input pulses. All power forinput devices (24V dc) is supplied by the I/O module.Applications: Any application requiring rotational control includingturbine generators, motors, drives, gears, shafts, etc.Description: A counter module with 2 incremental quadratureencoder interfaces, each with four inputs (A, B, Z, <strong>and</strong> G).Each input module has + inputs for connection to pulse transmitterswith complementary or non-complementary signals.The counter can count one or two pulse trains for up/down counting<strong>and</strong> detection of a selectable number of edges (X1, X2, X4). Each ofthe two counters has an upper limit of 100KHz, a 16-bit counterregister, a preset register, <strong>and</strong> a latch register.Power to the module is supplied from an external power supply.Applications: Typical applications include quantity counting,positioning, <strong>and</strong> speed calculations.Signal Types:Input = 12V to 24V square wave limited to 100KHzOutput = NoneNetwork Compatibility: All networks supported by <strong>FLEX</strong> I/OSignal Types:Input = 50mV, 500mV, 3V, 6V, 24V sine or square waveup to 32KHz Output = Two 24V dc digital source outputscurrent-limited to 1ANetwork Compatibility: All networks supported by <strong>FLEX</strong> I/O1794-VHSCDescription: A counter module with two incremental quadratureencoder interfaces, each with three inputs (A, B, <strong>and</strong> Z). Each inputmodule as + inputs for connection to pulse transmitters withcomplementary or non-complementary signals.The counter can count one or two pulse trains for up/down counting<strong>and</strong> detection of a selectable number of edges (X1, X2, X4). Each ofthe two counters has an upper limit of 1MHz, a 24-bit counter register,a preset register, <strong>and</strong> a latch register.Power to the module is supplied from an external power supply.Outputs can be configured for overlapping, multiple windows, <strong>and</strong>/orpulse with modulation.Applications: Typical applications include packaging, materialh<strong>and</strong>ling, flow monitoring, cut-to-length, motor speed control <strong>and</strong>monitoring.Signal Types:Input = 5V, 15V, or 24V dc square wave limited to 1MHzOutput = Four 5V or 12-24V dc digital source outputs,on-state current maximum 1A, maximum current peroutput pair is.5ANetwork Compatibility: Use with 1794-ACN(R)15 ControlNet only.1794-IP4Description: A counter module with 4 pulse transmitter interfaces(12-24V dc), each with two signal inputs (N <strong>and</strong> D).Each input module has + inputs for connection to pulse transmitters.Each interface may be configured for: a) period of time measurementusing one 16-bit counter <strong>and</strong> accumulating pulse counting using theother 16-bit counter or b) period time measurement using a 32-bitcounter.The number of periods to be measured is selectable (1, 2, 4, 8, 16, 32,64, <strong>and</strong> 128) via the gate control.Power to the module is supplied from an external power supply.Applications: Typical applications include counting pulses from flowmeters <strong>and</strong> density meters. Quantity counting <strong>and</strong> speed calculationsare examples of other applications.Signal Types:Input = 12V to 24V square wave limited to 100KHzOutput = NoneNetwork Compatibility: All networks supported by <strong>FLEX</strong> I/OPublication 1794-2.1 - January 2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!