12.07.2015 Views

FLEX I/O and FLEX Integra

FLEX I/O and FLEX Integra

FLEX I/O and FLEX Integra

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

74 24V dc 16 Source Output Module Cat. No. 1794-OB16 <strong>FLEX</strong> I/O <strong>and</strong> <strong>FLEX</strong> <strong>Integra</strong> Product DataSpecifications - 1794-OB16Number of Outputs 16 (1 group of 16), non-isolated, sourcingModule LocationCat. No. 1794-TB2, -TB3, or -TB3STerminal Base UnitON-State Voltage Range 10V dc minimum24V dc nominal;31.2V dc maximumON-State Voltage Drop 0.5V dc maximumON-State Current1.0mA minimum per channel500mA maximum per channelOFF-State Voltage31.2V dc maximumOFF-State Leakage0.5mA maximumIsolation Voltage (min) 100% tested at 850V dc for 1s between user <strong>and</strong>systemNo isolation between individual channelsOutput Signal DelayOFF to ONON to OFFFlexbus Current (max)0.5ms maximum1.0ms maximum80mAPower Dissipation 5.3W maximum @ 31.2VThermal Dissipation 18.1 BTU/hr @ 31.2V dcIndicators (field side 16 yellow status indicatorsindication, logic driven)Output Current Rating 8A (16 outputs @ 0.5A) horizontal or verticalSurge Current2A for 50ms, repeatable every 2 secondsKeyswitch Position 2Fusing 1SAN-O MQ4-800mAGeneral SpecificationsExternal dc PowerSupply VoltageVoltage RangeSupply CurrentDimensions HxWxDEnvironmental ConditionsOperational TemperatureStorage TemperatureRelative HumidityShock OperatingNon-operatingVibrationConductors Wire SizeCategoryPublicationInstallation Instructions 1794-5.3Agency Certification24V dc nominal19.2 to 31.2V dc (includes 5% ac ripple)49mA @ 24V dc (38mA to 65mA)46mm x 94mm x 53mm (1.8in x 3.7 in x 2.1in)0 to 55 o C (32 to 131 o F)-40 to 85 o C (-40 to 185 o F)5 to 95% noncondensing30g peak acceleration, 11(±1)ms pulse width50g peak acceleration, 11(±1)ms pulse widthTested 5g @ 10-500Hz per IEC 68-2-612 gauge (4mm 2 ) str<strong>and</strong>ed maximum3/64 inch (1.2mm) insulation maximum2 2Class I Division 2 certifiedGroups A, B, C, D certifiedClass I Zone 2 Group IIC certified1 Module outputs are not fused. Fusing of outputs is recommended. If external fusing isdesired, you must provide external fusing.2 Use this conductor category information for planning conductor routing. Refer topublication 1770-4.1, “Industrial Automation Wiring <strong>and</strong> Grounding Guidelines for NoiseImmunity.”Publication 1794-2.1 - January 2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!