12.07.2015 Views

Review of Environmental Factors - Transport for NSW - NSW ...

Review of Environmental Factors - Transport for NSW - NSW ...

Review of Environmental Factors - Transport for NSW - NSW ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Summary <strong>of</strong> Estimated RF EME Levels around the ProposedRailCorp DTRS Site at Wollongong, <strong>NSW</strong> 2500Introduction: Date 16/02/2012 NSA Site No (052)This report summarises the estimated maximum cumulative radi<strong>of</strong>requency (RF) electromagnetic energy (EME) levels atground level emitted from the proposed RailCorp DTRS Site at Wollongong, <strong>NSW</strong> 2500. Maximum EME levels are estimatedin 360° circular bands out to 500m from the base station. The procedures <strong>for</strong> making the estimates have been developed bythe Australian Radiation Protection And Nuclear Safety Agency (ARPANSA) 1 . These are documented in the ARPANSATechnical Report; “Radio Frequency EME Exposure Levels - Prediction Methodologies” which is available athttp://www.arpansa.gov.auEME Health StandardARPANSA, an Australian Government agency in the Health and Ageing portfolio has established a Radiation ProtectionStandard 2 specifying limits <strong>for</strong> continuous exposure <strong>of</strong> the general public to RF transmissions at frequencies used by mobilephone base stations. Further in<strong>for</strong>mation can be gained from the ARPANSA web site.The Australian Communications and Media Authority (ACMA) 3 mandates exposure limits <strong>for</strong> continuous exposure <strong>of</strong> thegeneral public to RF EME from mobile phone base stations. Further in<strong>for</strong>mation can be found at the ACMA websitehttp://emr.acma.gov.auProposed Site Radio SystemsDTRS 1800 - RailCorpTable <strong>of</strong> Predicted EME Levels – ProposedDistance from the antennas at Wollongongin 360° circular bands0m to 50m50m to 100m100m to 200m200m to 300m300m to 400m400m to 500mMaximum Cumulative EME Level – All carriers at this site(% <strong>of</strong> ARPANSA exposure limits 2 )Public exposure limit = 100%0.00097%0.0018%0.015%0.012%0.0055%0.0031%ReleasedBy: EGUGL InfrastructureDate: 17/02/2012 <strong>Review</strong>ers: PDMaximum EME level160.0 m, from the antennas at Wollongong 0.015%Table: Estimation <strong>for</strong> the maximum level <strong>of</strong> RF EME at 1.5m above the ground from the proposed antennas assuming level ground. Theestimated levels have been calculated on the maximum capacity anticipated <strong>for</strong> this site. This estimation does not include possible radio signalattenuation due to buildings and the general environment. The actual EME levels will generally be significantly less than predicted due to pathlosses and the base station automatically minimising transmitter power to only serve established phone calls 4 . Where applicable, particularlocations <strong>of</strong> interest in the area surrounding the base station, including topographical variations, are assessed in Appendix A “ Other areas <strong>of</strong>Interest” table on the last page.Summary – Proposed Radio SystemsRF EME levels have been estimated from the proposed antennas at Wollongong <strong>NSW</strong> 2500. The maximum cumulative EMElevel at 1.5 m above ground level is estimated to be 0.015 % <strong>of</strong> the ARPANSA public exposure limits.<strong>Environmental</strong> EME report (2007 ARPANSA Format) Page 1 <strong>of</strong> 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!