12.07.2015 Views

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 120 / 295Document ID.No.UKEPR-0002-162 Issue 04SUB-SECTION <strong>16.2</strong>.2.3 - TABLE 3Hydrogen release and temperature for various scenariosScenarioLOOP with reflood5 cm (20 cm 2 )SB(LOCA)cold leg f.s.c.5 cm (20 cm 2 )SB(LOCA)cold leg f.s.c.with reflood5 cm (20 cm 2 )SB(LOCA) p.c.with delayeddepressurisationMass of hydrogenreleased1000 kg760 kgMajor findingWall temperature: 89 ° C to 121 ° CGas temperature in the dome around 200 ° CWall temperature: 66 ° C to 90 ° CGas temperature in the dome around 185 ° C920 kg Wall temperature > 100 ° C850 kg up to corequenchingWall temperature < 121 ° C(p.c.: partial cooldown, f.s.c.: fast secondary cooldown; shaded rows: bounding scenarios)