12.07.2015 Views

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 56 / 295Document ID.No.UKEPR-0002-162 Issue 04SECTION <strong>16.2</strong>.2.1 - TABLE 11Event chronology for core melt scenarios without mitigation no PDS-line opening(MAAP 4 code) [Ref]Core oxidationonsetCore meltingStart of corerelocation intolower headAccumulator/injection /depletionMHSI/LHSI shutoffreachedVessel failureSB LOCA COLD LEG ONLY 4 SG PARTIAL SECONDARY COOLDOWN2.5 cm cold leg(5 cm²)3.8cm cold leg(11.4 cm²)5 cm cold leg(20 cm²)7.5 cm cold leg(46 cm²)8h36min3h45min2h07min1h54min8h39min3h52min2h13min2h41min11h42min7h35min9h51min6h21min9h36min /13h20min4h / 8h12min2h13min / 9h51min57min / 4h17min23min / 13h19min 17min / 8h12min 14min / 5h24min 11min / 2h15min13h18min8h12min12h26mn7h47min