SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 172 / 295Document ID.No.UKEPR-0002-162 Issue 04SUB-SECTION <strong>16.2</strong>.2.4 – TABLE 9Calculated steaming rate for the two flooding rates of 50 kg/s (top) and 100 kg/s (bottom)The data in this table are principally applicable, but relate to the case of 10 cm sacrificialconcrete. Data for 15 cm layer thickness are also available [Ref]PeriodSteaming rate0-2246 s 50 kg/s2246 – 8434 s 0> 8434 s 11 kg/sPeriodSteaming rate0-986 s 100 kg/s986 – 7174 s 0> 7174 s 11 kg/s