SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 232 / 295Document ID.No.UKEPR-0002-162 Issue 04SUB-SECTION <strong>16.2</strong>.2.5 - FIGURE 13LOOP containment gas temperature [Ref]200Ac4 Annular Comp. L3+L4Ac7 DomeEq10 Lower Equipm. Comp. L3Eq14 Upper Equipm. Comp. L3+L4Eq7 Upper Equipm. Comp. L1+L2150Temperature / °C100500 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000Time / s