SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 192 / 295Document ID.No.UKEPR-0002-162 Issue 04SUB-SECTION <strong>16.2</strong>.2.4 – FIGURE 20Axial ablation front progression during MCCI in the core catcher (LB(LOCA) case) [Ref]0.10.075Axial Ablation Depth, m0.050.025Fill-up of bottom cooling structure complete (two valves)Fill-up of bottom cooling structure complete (one valve)016000 16500 17000 17500 18000 18500Time after Scram , s