12.07.2015 Views

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 52 / 295Document ID.No.UKEPR-0002-162 Issue 04SECTION <strong>16.2</strong>.2.1 - TABLE 7Event chronology for core melt scenarios without in-vessel reflooding (MAAP 4 Code)- SG partial and fast secondary cooldown [Ref]One PDS lineopeningCore uncoveryAccumulatordepletionCore melt onsetStart of corerelocation intolower headFirst vesselfailureLOCAcold leg 5 cm(20 cm²)24h19min20h37min35 min25h28h31min30h07minLOCAcold leg 7.5cm(46 cm²)LOCAhot leg 5 cm(20 cm²)Full power, 1 SG feed9h45min12h52min8h12min9h30min35 min3h17min9h58min13h03min12h35min15h55min13h54min18h37minLOCAhot leg 7.5cm(46 cm²)4h58min3h36min35 min5h10min7h40min8h41minLOCAcold leg 5 cm(20 cm²)Full power, 4SG fed40h18min38h46min33 min40h21min43h23min46h18minLOCAhot leg 7.5 cmpressuriserbreakFull power, 1SG fed14h27min11h56min34min14h39min17h33min17h45minSGTR onedouble endedtube48h45min47h59min4h47min49h36min56h56min58h31min