12.07.2015 Views

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

16.2 - Severe Accident Analysis (RRC-B) - EDF Hinkley Point

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SUB-CHAPTER : <strong>16.2</strong>PRE-CONSTRUCTION SAFETY REPORTCHAPTER 16: RISK REDUCTION AND SEVEREACCIDENT ANALYSESPAGE : 170 / 295Document ID.No.UKEPR-0002-162 Issue 04SUB-SECTION <strong>16.2</strong>.2.4 – TABLE 7Selected CORFLOW results regarding melt properties at t = 1 min after spreading forparametric study (cases 1-3) [Ref]Case 1a Case 1b Case 2 Case 3Variable Unit Metal Oxide+Slag OxideMixed(Ref.)Maximum fluid temperature K 2521 2489 2709 2567Minimum fluid temperature K 1723 2311 2368 2300Maximum fluid liquid fraction - 1 0.97 0.65 0.995Minimum fluid liquid fraction - 0.52 0.91 0 0.777Decay heat produced GJ 0.235 0.694 0.694 0.929Heat removed by conduction GJ 12.3 0.91 2.57 3.48Heat removed by radiation GJ 4.5 9.2 13 10.8